A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of buprenorphine LUCIO immunoassay versus GC-MS using urines from a workplace drug testing program. | LitMetric

Evaluation of buprenorphine LUCIO immunoassay versus GC-MS using urines from a workplace drug testing program.

J Anal Toxicol

Faculty of Pharmaceutical Science of Ribeirão Preto, São Paulo University, Cafè Avenue, Ribeirão Preto 14040-903, São Paulo, Brazil.

Published: April 2013

The buprenorphine (BUP) LUCIO Nal Von Minden screening assay was evaluated. Urine samples from subjects enrolled in a workplace drug testing program were screened according to the manufacturer's instruction using a Roche COBAS Integra 800 analyser. For gas chromatography-mass spectrometry (GC-MS) confirmatory analysis, samples were submitted to enzymatic hydrolysis with β-glucuronidase and mixed-mode solid-phase extraction. Imprecision (coefficient of variation) for 3.0, 7.0, and 13.0 ng/mL calibrators varied within 2.8-8.7 intra-day (n = 20) and 7.7-8.6 inter-day (n = 19). Inaccuracy (bias) was between -5.6-30.5 intra-day and -13.2-4.2 inter-day. At the 5 ng/mL cut-off, the immunoassay showed 100% sensitivity and 88% specificity, with an overall agreement of 94% between immunoassay and GC-MS. Raising the cut-off to 10 ng/mL provided an identical overall agreement between immunoassay and GC-MS (94%), despite the decrease in sensitivity (90%) and the increase in specificity (100%). According to these results, the BUP LUCIO Nal Von Minden screening assay provides adequate sensitivity and specificity for BUP screening in urine samples using a cut-off concentration of 5 ng/mL.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/bkt006DOI Listing

Publication Analysis

Top Keywords

workplace drug
8
drug testing
8
testing program
8
bup lucio
8
lucio nal
8
nal von
8
von minden
8
minden screening
8
screening assay
8
urine samples
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!