Transcatheter double stent implantation for treatment of middle aortic coarctation syndrome.

Catheter Cardiovasc Interv

Department of Paediatric Cardiology, Our Lady's Children's Hospital, Crumlin, Dublin 12, Ireland.

Published: October 2013

A 13-year-old boy presented with severe systemic hypertension. His upper limb blood pressure measured 190/100 mm Hg and lower limb blood pressure measured 98/64 mm Hg. The brachial pulses were bounding and femoral pulses were not palpable. Echocardiography and magnetic resonance angiography confirmed middle aortic syndrome. There was severe diffuse thoraco-abdominal coarctation with continuous Doppler run-off. Cardiac catheterization was undertaken and using a retrograde approach two Advanta V12 stents were implanted in the complex thoraco-abdominal coarctation. The gradient across the coarctation was reduced from 80 to 40 mm Hg gradient with a significant improvement in the luminal diameter of the aorta. His upper limb blood pressure reduced to 142/78 mm Hg six weeks later.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.24857DOI Listing

Publication Analysis

Top Keywords

limb blood
12
blood pressure
12
middle aortic
8
upper limb
8
pressure measured
8
thoraco-abdominal coarctation
8
transcatheter double
4
double stent
4
stent implantation
4
implantation treatment
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?