Background: Treatment of hepatocellular carcinoma (HCC) in the setting of cirrhosis is limited by tumor size/location and underlying liver disease. Radiofrequency ablation is utilized in selected patients; however, local recurrence remains a concern. Microwave ablation (MWA) delivers energy to tissue in a unique fashion, reducing local recurrence. A minimally invasive operative approach allows for mobilization/protection of adjacent structures, intra-operative ultrasound, and assessment of ablation progress.

Study Design: Retrospective review of operative MWA performed for HCC in patients with cirrhosis over a 4-year period at a single center. Complications were stratified by Clavien-Dindo classification. Incomplete ablation and local, regional, and metastatic recurrence was assessed on follow-up imaging. Survival was assessed in months.

Results: Fifty-four patients with 73 tumors underwent MWA. Median tumor size was 2.6 cm (range 0.5-8.5 cm). Cirrhosis was present in 92.6 % of patients, with a Child-Pugh score of B/C in 27.8 % and hepatitis C present in 59.3 %. A minimally invasive approach was used in 94.5 % of patients. There were no deaths within 30 days. Thirty-day morbidity was 28.9 %, with grade III complications present in 11.5 %. Delayed complications occurred in 7.8 % of patients, with a 5.6 % 90-day mortality. Incomplete ablation was identified in 5.9 % of tumors with local recurrence of 2.9 % at 9 months median follow-up. Regional and metastatic recurrence occurred in 27.5 and 11.8 % at 9 months median follow-up. Median survival was not reached at 11 months median follow-up. One- and 2-year survival was 72.3 and 58.8 %.

Conclusion: Operative, preferably minimally invasive, MWA can be performed in cirrhotic patients with HCC with acceptable morbidity and low recurrence rates. High regional and metastatic recurrence rates in these patients underscore the need for minimally invasive, low morbidity approaches to liver-directed therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11605-013-2164-yDOI Listing

Publication Analysis

Top Keywords

minimally invasive
16
local recurrence
12
regional metastatic
12
metastatic recurrence
12
median follow-up
12
microwave ablation
8
hepatocellular carcinoma
8
recurrence
8
patients
8
mwa performed
8

Similar Publications

Background: Robotic assistance has become increasingly prevalent in spinal surgery in recent years, emerging as a tool to increase accuracy and precision and lower complication rates and radiation exposure. The 7 and 8 Annual Seattle Science Foundation (SSF) Robotics Courses showcased presentations and demonstrations from some of the field's most experiences leaders on latest topics in robotics and spinal surgery, including cutting-edge preoperative planning technologies, augmented reality (AR) in the operating room, cervical fusion with transpedicular screws, and neuro-oncologic management. We provide a scoping review of the use of robotics technology in spinal surgery featuring highlights from the 7 and 8 Annual SSF Robotics Courses.

View Article and Find Full Text PDF

Background: Prone lateral spinal surgery for simultaneous lateral and posterior approaches has recently been proposed to facilitate surgical room efficiency. The purpose of this study is to evaluate the feasibility and outcomes of minimally invasive prone lateral spinal surgery using a rotatable radiolucent Jackson table.

Methods: From July 2021 to June 2023, a consecutive series of patients who received minimally invasive prone lateral spinal surgery for various etiologies by the same surgical team were reviewed.

View Article and Find Full Text PDF

Background: Robotic-assisted spinal surgery has reportedly improved the accuracy of instrumentation with smaller incisions, improving surgical outcomes and reducing hospital stay. However, robot-assisted spine surgery has thus far been confined to placement of pedicle screw instrumentation only. This pilot study aims to explore the feasibility of utilizing the Mazor™ X Stealth Edition (Medtronic, Sofamor Danek USA), robotic-arm platform in the minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) procedure inclusive of interbody cage placement, in our institution.

View Article and Find Full Text PDF

Background And Objective: As the global population ages, degenerative spinal disorders are on the rise, leading to an increased focus on optimizing spinal fusion therapies. Despite the high success rate of iliac crest bone autografts, their usage is hampered by donor site morbidity and limited supply. The objective of this review is to assess the viability of ceramic-based synthetic materials as alternatives in spinal fusion surgeries.

View Article and Find Full Text PDF

Background: Surgical treatment of therapy-resistant radiculopathy associated with lumbar herniated discs in patients with extreme obesity is a challenge for neurosurgeons. In addition to technical problems in surgery due to the abundant subcutaneous adipose tissue and perioperative risks, there are significant anesthetic risks when anesthesia is performed with a patient in the prone position. A surgical procedure should preferably be minimally traumatic and quick with minimal risks of complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!