Background/aim: Primary open-angle glaucoma is a multifactorial and progressive neuropathy, characterised by the acquired loss of ganglion cells of the retina and their axons. One of the risk factors for primary open-angle glaucoma is myopia over 5 diopters (D). The aim of our work was to investigate two groups of patients with primary open-angle glaucoma and myopia by using confocal scanning laser ophthalmoscopy, and to find out if the size of refractive error influences optic disk morfometric characteristics.

Methods: One hundred eyes of one hundred patients with primary open-angle glaucoma and myopia were involved in our study. All the patients were classified into two groups, the first one with myopia < 5 D, and the second one with myopia > or = 5 D. The Heidelberg retina tomograph is a technique we used in our study. We analized morfometric parameters of patients optic discs, with the aim to find a correlation between the parameters in each group separeatly, and also to find differences between the same parameters from both groups.

Results: There were significant differences in disc area, cup area, rim area and mean RNFL thickness between the two groups. The size of damage of neuroretinal rim in the group with high myopia was 27%, and in the group with lower myopia 14%. The most frequently damaged segment of neuroretinal rim in the patients with high myopia was nasal segment and in the patients with low myopia infero-temporal one. The least frequently damaged segment of neuroretinal rim in both groups was temporal one.

Conclusion: Optic discs of glaucomatous patients with high myopia have bigger diameter, also bigger and more irregularly distributed damaged zone of neuroretinal rim, and also thinner retinal nerve fiber layer compared to glaucomatous patients with lower myopia.

Download full-text PDF

Source
http://dx.doi.org/10.2298/vsp111229024gDOI Listing

Publication Analysis

Top Keywords

primary open-angle
20
open-angle glaucoma
20
neuroretinal rim
16
myopia
12
glaucoma myopia
12
high myopia
12
patients
9
patients primary
8
optic discs
8
lower myopia
8

Similar Publications

Purpose: To assess the efficacy and safety of PreserFlo MicroShunt (PMS) combined with mitomycin C in patients with medically treated primary open-angle glaucoma (POAG).

Study Design: A retrospective observational study.

Methods: The study examined 83 eyes from 83 patients with medically treated glaucoma surgery naive POAG.

View Article and Find Full Text PDF

Background/ Aims: To analyze the longitudinal change in Bruch's membrane opening minimal rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (pRNFL) thickness using optical coherence tomography (OCT) after implantation of a PRESERFLO® microshunt for surgical glaucoma management in adult glaucoma patients.

Methods: Retrospective data analysis of 59 eyes of 59 participants undergoing implantation of a PRESERFLO microshunt between 2019 and 2022 at a tertiary center for glaucoma management. Surgical management included primary temporary occlusion of the glaucoma shunt to prevent early hypotony.

View Article and Find Full Text PDF

Prcis: Trabecular cutting minimally invasive glaucoma surgery like bent ab interno needle goniectomy (BANG) when performed in baseline aqueous angiography identified low aqueous humor outflow regions, results in greater success of intraocular pressure reduction.

Purpose: To study the efficacy of Bent Ab Interno Needle Goniectomy (BANG) in high versus low aqueous humor outflow (AHO) regions as determined by Aqueous Angiography(AA) in patients with primary open angle glaucoma (POAG).

Methods: A prospective, single-centre, pilot, randomized control trial recruited 30 eyes of 30 patients of POAG and visually significant cataract (45-80 y) and were randomised into two groups ("A": BANG performed in the high-flow regions and "B": BANG performed in the low-flow regions) of 15 each.

View Article and Find Full Text PDF

Introduction: This retrospective, consecutive, real-world case series assessed the efficacy and safety of third-generation trabecular micro-bypass stent implantation (iStent infinite) with phacoemulsification in patients with mild-to-moderate primary open-angle glaucoma (POAG).

Methods: Patients underwent phacoemulsification combined with implantation of iStent infinite (containing three stents) by a single U.S.

View Article and Find Full Text PDF

This retrospective study investigated the risk of primary open-angle glaucoma (POAG) among individuals identified as glaucoma suspects and examined associated cardiovascular risk factors. We conducted a longitudinal, nationwide cohort study using data from the Korean National Health Insurance Service (KNHIS) and included 362,285 participants aged ≥ 40 years from the Korean National Health Screening Program (NHSP) without pre-existing POAG in 2009 and 2010. Of these, glaucoma suspects (n = 32,220) were defined as individuals with at least two recorded instances of the KCD code H400 for glaucoma suspect and no prior antiglaucoma medication prescriptions before health screening.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!