Mini review of ultrafast fluorescence polarization spectroscopy [invited].

Appl Opt

Institute for Ultrafast Spectroscopy and Lasers, Department of Electrical Engineering, The City College of the City University of New York, New York, New York 10031, USA.

Published: February 2013

A mini review is presented on the theory, experiment, and application of the ultrafast fluorescence polarization dynamics and anisotropy with examples of two important medical dyes, namely Indocyanine Green and fluorescein. The time-resolved fluorescence polarization spectra of fluorescent dyes were measured with the excitation of a linearly polarized femtosecond laser pulse, and detected using a streak camera. The fluorescence emitted from the dyes is found to be partially oriented (polarized), and the degree of polarization of emission decreases with time. The decay of the fluorescence component polarized parallel to the excitation beam was found to be faster than that of the perpendicular one. Based on the physical model on the time-resolved polarized emission spectra in nanosecond range first described by Weber [J. Chem. Phys.52, 1654 (1970)], a set of first-order linear differential equations was used to model fluorescence polarization dynamics and anistropy of dye in picoseconds range. Using this model, two important decay parameters were identified separately: the decay rate of total emission intensity and the decay rate of the emission polarization affected by the rotation of fluorescent molecules causing the transfer of emission polarization from one orthogonal component to another. These two decay rates were separated and extracted from the measured time-resolved fluorescence polarization spectra. The emission polarization difference among dyes arising from different molecular volumes was used to enhance the image contrast.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.52.000917DOI Listing

Publication Analysis

Top Keywords

fluorescence polarization
20
emission polarization
12
polarization
9
mini review
8
ultrafast fluorescence
8
polarization dynamics
8
time-resolved fluorescence
8
polarization spectra
8
decay rate
8
fluorescence
7

Similar Publications

Fluorescence polarization assays to study carbohydrate-protein interactions.

Org Biomol Chem

January 2025

Glycosystems Laboratory, Instituto de Investigaciones Químicas (IIQ), cicCartuja, CSIC and Universidad de Sevilla, Americo Vespucio, 49, 41092 Sevilla, Spain.

Fluorescence polarization (FP) is a useful technique to study the interactions between carbohydrates and proteins in solution, by using standard equipment and minimal sample consumption. Here, we will review the most recent FP-based approaches in this field, including the study of carbohydrate-lectin, carbohydrate-enzyme and glycosaminoglycan-protein interactions. Advantages and limitations of this methodology will be discussed.

View Article and Find Full Text PDF

Biological applications using multiphoton microscopy increasingly seek a larger field of view while maintaining sufficient temporal sampling to observe dynamic biological processes. Multiphoton imaging also requires high numerical aperture microscope objectives to realize efficient non-linear excitation and collection of fluorescence. This combination of low-magnification and high-numerical aperture poses a challenge for system design.

View Article and Find Full Text PDF

The 2200-nm window has recently been demonstrated as the longest excitation window for deep-tissue multiphoton microscopy (MPM). So far, MPM at this window exclusively uses a soliton laser source based on soliton self-frequency shift (SSFS). In order to boost the multiphoton signal level at this window, here we demonstrate a polarization multiplexed soliton source based on orthogonal polarized SSFS in a polarization maintaining large mode area (PM LMA) fiber.

View Article and Find Full Text PDF

In recent years, studies of surfaces at more realistic conditions has advanced significantly, leading to an increased understanding of surface dynamics under reaction conditions. The development has mainly been due to the development of new experimental techniques or new experimental approaches. Techniques such as High Pressure Scanning Tunneling/Force Microscopy (HPSTM/HPAFM), Ambient Pressure X-ray Photo emission Spectroscopy (APXPS), Surface X-Ray Diffraction (SXRD), Polarization-Modulation InfraRed Reflection Absorption Spectroscopy (PMIRRAS) and Planar Laser Induced Fluorescence (PLIF) at semi-realistic conditions has been used to study planar model catalysts or industrial materials under operating conditions.

View Article and Find Full Text PDF

The current work presents comparative assessment of affinity of the designed DNA aptamers for extracellular domain of the human epidermal growth factor receptor (EGFR*). The affinity data of the 20 previously published aptamers are summarized. Diversity of the aptamer selection methods and techniques requires unification of the comparison algorithms, which is also necessary for designing aptamers used in the post-selection fitting to the target EGFR* protein.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!