To bin or not to bin? The effect of CT system limiting resolution on noise and detectability.

Phys Med Biol

School of Integrated Technology, Yonsei University, 406-840 Incheon, Korea.

Published: March 2013

We examine the noise advantages of having a computed tomography (CT) detector whose spatial resolution is significantly better (e.g. a factor of 2) than needed for a desired resolution in the reconstructed images. The effective resolution of detectors in x-ray CT is sometimes degraded by binning cells because the small cell size and fine sampling are not needed to achieve the desired resolution (e.g. with flat panel detectors). We studied the effect of the binning process on the noise in the reconstructed images and found that while the images in the absence of noise can be made identical for the native and the binned system, for the same system MTF in the presence of noise, the binned system always results in noisier reconstructed images. The effect of the increased noise in the reconstructed images on lesion detection is scale (frequency content) dependent with a larger difference between the high resolution and binned systems for imaging fine structure (small objects). We show simulated images reconstructed with both systems for representative objects and quantify the impact of the noise on the detection of the lesions based on mathematical observers. Through both subjective assessment of the reconstructed images and the quantification using mathematical observers, we show that for a CT system where the photon noise is dominant, higher resolution in the detectors leads to better noise performance in the reconstructed images at any resolution.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/58/5/1433DOI Listing

Publication Analysis

Top Keywords

reconstructed images
24
noise
9
resolution
8
desired resolution
8
images
8
resolution detectors
8
noise reconstructed
8
binned system
8
mathematical observers
8
reconstructed
7

Similar Publications

Determining the level of consciousness in patients with brain injury-and more fundamentally, establishing what they can experience-is ethically and clinically impactful. Patient behaviors may unreliably reflect their level of consciousness: a subset of unresponsive patients demonstrate covert consciousness by willfully modulating their brain activity to commands through fMRI or EEG. However, current paradigms for assessing covert consciousness remain fundamentally limited because they are insensitive, rely on imperfect assumptions of functional neuroanatomy, and do not reflect the spectrum of conscious experience.

View Article and Find Full Text PDF

Background And Objectives: A typical workflow for deep brain stimulation (DBS) surgery consists of head frame placement, followed by stereotactic computed tomography (CT) or MRI before surgical implantation of the hardware. At some institutions, this workflow is prolonged when the imaging scanner is located far away from the operating room, thereby increasing workflow times by the addition of transport times. Recently, the intraoperative O-arm has been shown to provide accurate image fusion with preoperative CT or MR imaging, suggesting the possibility of obtaining an intraoperative localization scan and postoperative confirmation.

View Article and Find Full Text PDF

Case: A 48-year-old man with multiple injuries sustained a Gustilo type 3A right open distal humerus fracture with a 4-cm wound, contralateral radius shaft, and ilium fractures. Following wound irrigation on the day of injury, second look debridement showed crushed triceps and severe contamination extending into the distal humerus medullary canal. After 6 days of initial plate fixation, he developed signs of deep infection.

View Article and Find Full Text PDF

Applications of mass spectrometry imaging in botanical research.

Adv Biotechnol (Singap)

February 2024

State Key Laboratory of Traditional Chinese Medicine/School of Pharmaceutical Sciences, Guangzhou University of Chinese Medicine, Guangzhou, 510006, China.

Mass spectrometry imaging (MSI) serves as a valuable tool enabling researchers to scrutinize various compounds, peptides, and proteins within a sample, providing detailed insights at both elemental and molecular levels. This innovative technology transforms information obtained from a mass spectrometer- encompassing ionic strength, mass-to-charge ratio, and ionized molecule coordinates-within a defined region into a pixel-based model. Consequently, it reconstructs the spatial distribution of ions, allowing for a comprehensive understanding of molecular landscapes.

View Article and Find Full Text PDF

A review of state-of-the-art resolution improvement techniques in SPECT imaging.

EJNMMI Phys

January 2025

Department of Nuclear Medicine, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, 230001, Anhui, China.

Single photon emission computed tomography (SPECT), a technique capable of capturing functional and molecular information, has been widely adopted in theranostics applications across various fields, including cardiology, neurology, and oncology. The spatial resolution of SPECT imaging is relatively poor, which poses a significant limitation, especially the visualization of small lesions. The main factors affecting the limited spatial resolution of SPECT include projection sampling techniques, hardware and software.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!