Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To characterize the rotator cable high-resolution ultrasound appearance in asymptomatic shoulders of volunteers of different age.
Materials And Methods: IRB approval and volunteers' written consent was obtained. Excluding subjects with known shoulder affections, we screened 24 asymptomatic volunteers. Supraspinatus and infraspinatus tendons high-resolution ultrasound evaluation was performed according to standard scan protocols, further excluding shoulders with partial/full-thickness cuff tears. Thus, we studied 24 shoulders in 12 young volunteers (age range 21-39 years, mean age 33 ± 8 years) and 21 shoulders in 11 elderly volunteers (age range 62-83 years, mean age 75 ± 45 years). For each shoulder, we noted rotator cable visibility and its thickness and width. Fisher's and U Mann-Whitney statistics were used.
Results: Rotator cable was less frequently detected in young than in elderly volunteers (5/24 vs. 11/21 shoulders; P = 0.034). When detected, rotator cable was significantly thicker in young (range 1.2-1.5 mm, mean thickness 1.3 ± 0.1 mm) than in elderly (range 0.9-1.4 mm, mean thickness 1.2 ± 0.1 mm) volunteers (P = 0.025), while its width was not significantly different in young (range 4.5-7.1 mm, mean 5.6 ± 1.1 mm) compared to elderly (range 2.5-7.1 mm, mean 4.2 ± 1.4 mm) volunteers (P = 0.074) although a tendency can be highlighted.
Conclusions: Ultrasound demonstrated the different consistency of rotator cable in young and elderly asymptomatic patients, with high interobserver reproducibility.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3558070 | PMC |
http://dx.doi.org/10.1016/j.jus.2012.01.003 | DOI Listing |