Tomographic scintigraphy using a pinhole collimator and a rotating gamma camera.

Nuklearmedizin

Department of Radiation Physics, University of Lund, Malmö, Sweden.

Published: March 1990

When a pinhole collimator is to be used for tomographic studies the standard SPECT software has to be modified so as to avoid serious image distortion outside the axis of rotation. The MTF measured at the axis of rotation shows that the better resolution of the pinhole collimator as compared with that of a parallel-hole collimator improves the tomographic image. The low sensitivity of the pinhole collimator excludes the use of an aperture smaller than 6 mm for patient tomographic studies where the activity which may be administered is restricted.

Download full-text PDF

Source

Publication Analysis

Top Keywords

pinhole collimator
16
tomographic studies
8
axis rotation
8
collimator
5
tomographic
4
tomographic scintigraphy
4
pinhole
4
scintigraphy pinhole
4
collimator rotating
4
rotating gamma
4

Similar Publications

Purpose: We are developing a three-dimensional X-ray fluorescence computed tomography (3D XFCT) system using non-radioactive-labeled compounds for preclinical studies as a new modality that provides images of biological functions. Improvements in image quality and detection limits are required for the in vivo imaging. The aim of this study was to improve the quality of XFCT images by applying a deep image prior (DIP), which is a type of convolutional neural network, to projection images as a pre-denoising method, and then compare with DIP post-denoising.

View Article and Find Full Text PDF

The compact line-focus X-ray tube for microbeam radiation therapy - Focal spot characterisation and collimator design.

Phys Med

December 2024

Department of Radiation Oncology, TUM School of Medicine and Health and Klinikum rechts der Isar, TUM University Hospital, Technical University of Munich (TUM), Munich, Germany; Institute of Radiation Medicine, Helmholtz Zentrum München GmbH, German Research Center for Environmental Health, Neuherberg, Germany; Forschungs-Neutronenquelle Heinz Maier-Leibnitz Zentrum (FRM II), Technical University of Munich (TUM), Garching, Germany.

Purpose: Microbeam radiation therapy (MRT) has shown superior healthy tissue sparing at equal tumour control probabilities compared to conventional radiation therapy in many preclinical studies. The limitation to preclinical research arises from a lack of suitable radiation sources for clinical application of MRT due to high demands on beam quality. To overcome these limitations, we developed and built the first prototype of a line-focus X-ray tube (LFXT).

View Article and Find Full Text PDF

Imaging of scattered radiation sources in X-ray radiography using a semiconductor radiation visualization camera.

Radiol Phys Technol

December 2024

Division of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-Ku, Fukuoka, 812-8582, Japan.

Article Synopsis
  • The study aims to determine if X-ray imaging can effectively visualize scattered radiation using a semiconductor camera with image processing.
  • Experiments were conducted with a C-arm X-ray device and a portable camera, manipulating the height of a radiation protective board and the size of the irradiation field.
  • The findings showed that the camera could produce colored images representing scattered radiation intensity, confirming its potential for imaging applications.
View Article and Find Full Text PDF

Advanced pinhole collimation geometries optimized for preclinical high-energyimaging facilitate applications such asandemitter imaging, simultaneous multi-isotope PET and PET/SPECT, and positron range-free PET. These geometries replace each pinhole with a group of clustered pinholes (CPs) featuring smaller individual pinhole opening angles (POAs), enabling sub-mm resolution imaging up to ∼1 MeV. Further narrowing POAs while retaining field-of-view (FOV) may enhance high-energy imaging but faces geometrical constraints.

View Article and Find Full Text PDF

Prompt gammas imaging (PGI) is a promising method for observing a beam's shape and estimating the range of the beam from outside a subject. However 2-dimensional images of prompt gammas (PGs) during irradiation of protons were still difficult to measure. To achieve PGI, we developed a new gamma camera and imaged PGs while irradiating a phantom by proton beams.

View Article and Find Full Text PDF