Temperature dependence of gain and excess noise in InAs electron avalanche photodiodes.

Opt Express

Department of Electronic and Electrical Engineering, The University of Sheffield, Sir Frederick Mappin Building, Mappin Street, Sheffield. S1 3JD, UK.

Published: December 2012

Measurement and analysis of the temperature dependence of avalanche gain and excess noise in InAs electron avalanche photodiodes (eAPDs) at 77 to 250 K are reported. The avalanche gain, initiated by pure electron injection, was found to reduce with decreasing temperature. However no significant change in the excess noise was measured as the temperature was varied. For avalanche gain > 3, the InAs APDs with 3.5 µm i-region show consistently low excess noise factors between 1.45 and 1.6 at temperatures of 77 to 250 K, confirming that the eAPD characteristics are exhibited in the measured range of electric field. As the dark current drops much more rapidly than the avalanche gain and the excess noise remains very low, our results confirmed that improved signal to noise ratio can be obtained in InAs eAPDs by reducing the operating temperature. The lack of hole impact ionization, as confirmed by the very low excess noise and the exponentially rising avalanche gain, suggests that hole impact ionization enhancement due to band "resonance" does not occur in InAs APDs at the reported temperatures.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.20.029568DOI Listing

Publication Analysis

Top Keywords

excess noise
24
avalanche gain
20
gain excess
12
temperature dependence
8
noise inas
8
inas electron
8
electron avalanche
8
avalanche photodiodes
8
inas apds
8
low excess
8

Similar Publications

Exploring offshore particle motion soundscapes.

J Acoust Soc Am

January 2025

Center for Acoustics Research and Education, University of New Hampshire, Durham, New Hampshire 03823, USA.

Fishes and aquatic invertebrates utilize acoustic particle motion for hearing, and some additionally detect sound pressure. Yet, few underwater soundscapes studies report particle motion, which is often assumed to scale predictably with pressure in offshore habitats. This relationship does not always exist for low frequencies or near reflective boundaries.

View Article and Find Full Text PDF

Noise-induced hearing loss (NIHL) is primarily driven by inflammatory processes within the cochlea, where noise exposure triggers the activation of the NOD-like receptor protein 3 (NLRP3) inflammasome, leading to an inflammatory cascade. The interaction between increased NLRP3 expression and NF-κB activity can further amplify cochlear inflammation. Our findings reveal that (R)-PFI-2 hydrochloride, a selective inhibitor of the SETD7 enzyme, effectively inhibits the activation of the cochlear NF-κB pathway, suppresses the release of pro-inflammatory factors, and prevents inflammasome assembly.

View Article and Find Full Text PDF

Adversarial training has become a primary method for enhancing the robustness of deep learning models. In recent years, fast adversarial training methods have gained widespread attention due to their lower computational cost. However, since fast adversarial training uses single-step adversarial attacks instead of multi-step attacks, the generated adversarial examples lack diversity, making models prone to catastrophic overfitting and loss of robustness.

View Article and Find Full Text PDF

Objective: To assess the utility of a bespoke smartphone app to map noise and vibration exposure across neonatal road ambulance journeys.

Design And Setting: Prospective observational study of ambulance journeys across a large UK neonatal transport service. Smartphones, with an in-house developed app, were secured to incubator trolleys to collect vibration and noise data for comparison with international standards.

View Article and Find Full Text PDF

Dual-domain Wasserstein generative adversarial network with hybrid loss for low-dose CT imaging.

Phys Med Biol

January 2025

Capital Normal University, 105, North West Sanhuan Road, Haidian District, Beijing, Beijing, None Selected, 100048, CHINA.

Objective: Low-dose computed tomography (LDCT) has gained significant attention in hospitals and clinics as a popular imaging modality for reducing the risk of X-ray radiation. However, reconstructed LDCT images often suffer from undesired noise and artifacts, which can negatively impact diagnostic accuracy. This study aims to develop a novel approach to improve LDCT imaging performance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!