Aims: Following CRT, atrioventricular (AV) optimization is not routinely practised. To evaluate its clinical utility, we examined the effect of AV delay optimization on the prognostic biomarker NT-proBNP.
Methods And Results: We prospectively studied 72 patients (mean age 73 ± 12.5 years, 70.8% male, 55.6% ischaemic) undergoing iterative AV optimization. Patients were divided into those whose nominal setting appeared ideal and not changed (Group 1, n = 22) and those whose AV delay was optimized (Group 2, n = 50). All patients underwent NT-proBNP assessment prior to CRT, and pre- and a median 5 days post-optimization. Compared with Group 1, NT-proBNP fell significantly in Group 2 patients (median 474 pg/mL) following optimization (P = 0.00001). A significant change in filling pattern (defined as a change in AV delay >50 ms) was required in 30% of patients, and it was this subgroup that derived the greater reduction in NT-proBNP levels [-1407 pg/mL, interquartile range (IQR) -3042 to -346 pg/mL] compared with those requiring <50 ms AV delay change (-125 pg/mL, IQR -1038 to 6 pg/mL), P = 0.0011. The benefit of AV optimization was principally observed in reverse remodelling non-responders (median -2167 pg/mL, IQR -3042 to -305 pg/mL) and in patients with a pseudonormal or restrictive filling pattern (median -1407 pg/mL, IQR -2809 to -342 pg/mL), compared with those with more benign diastolic filling (median - 264 pg/mL, IQR -1038 to -21 pg/mL), P = 0.033.
Conclusions: In one-third of patients, major filling pattern changes are achieved with AV optimization, associated with subsequent rapid falls in NT-proBNP. The greater the AV delay change, the larger the NT-proBNP fall, and non-responders and those with restrictive or pseudonormal filling despite CRT are most likely to benefit.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/eurjhf/hft012 | DOI Listing |
J Cardiol Cases
October 2024
Second Division of Cardiology, Pisa University Hospital, Pisa, Italy.
Unlabelled: Corrected transposition of the great arteries (c-TGA) is a congenital abnormality characterized by atrioventricular (AV) and ventriculoarterial discordance, associated with early and late-onset conduction disturbances. We report the case of a c-TGA patient affected by congenital complete AV block, with right ventricular lead malfunction with prolonged dwell time and two abandoned leads. He underwent leadless VDD pacemaker implantation at an unusual site (i.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Cardiac Electrophysiology, National Medical Center 'November 20th', ISSSTE, Av. Felix Cuevas #540, Col. Del Valle Del. Benito Juarez, C.P. 03100 Mexico City, Mexico.
Background: The 'univentricular' heart encompasses a variety of congenital cardiac defects characterized by a single functional ventricle and an underdeveloped ventricular chamber. Surgical intervention, typically in infancy or childhood, aims to regulate pulmonary blood flow volume. In adulthood, untreated patients may experience limitations in physical activity and elevated morbidity due to persistent cyanosis and arrhythmias, notably after the Fontan procedure.
View Article and Find Full Text PDFAm J Case Rep
January 2025
Department of Anatomic Pathology and Cytopathology, University Hospital "Dr. José Eleuterio González", Monterrey, Mexico.
BACKGROUND Primary cardiac malignancies are extremely rare, with an incidence of 0.07% on autopsy series. Primary sarcomas represent up to 95% of malignant neoplasms, with myxofibrosarcomas accounting for only 10%.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary.
Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.
Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.
ESC Heart Fail
December 2024
Boston Scientific Corporation, St. Paul, Minnesota, USA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!