Purpose: The purpose of this study was to evaluate the effect of simulated disinfections (2% glutaraldehyde, 1% sodium hypochlorite, and microwave energy) on the surface hardness of Trilux, Biocler, Biotone, New Ace, and Magister commercial artificial teeth.

Materials And Methods: Specimens (n = 10) were made with the teeth included individually in circular blocks of acrylic resin, leaving the labial surface exposed. Cycles of simulated chemical disinfection were accomplished with the specimens immersed in the solutions at room temperature for 10 minutes, followed by tap water washing for 30 seconds and storage in distilled water at room temperature for 7 days until the next disinfection. Simulated disinfection by microwave energy was carried out in a domestic oven with 1300 W at a potency of 50% for 3 minutes with the specimens individually immersed in 150 ml of distilled water. Control (no disinfection) and the experimental groups (first and third disinfection cycles) were submitted to Knoop hardness measurements with indentations at the center of the labial tooth surface. Data were submitted to repeated measure two-way ANOVA and Tukey's test (α = 0.05).

Results: Biocler, Magister, and Trilux showed lower surface microhardness when submitted to microwave. Lower microhardness for Biotone was promoted by hypochlorite, while no significant difference was shown for New Ace. The third disinfection cycle significantly decreased the tooth surface hardness only for microwave.

Conclusions: Different disinfection methods promoted different effects on the microhardness of different types of artificial teeth. Surface microhardness of the teeth was less affected by the simulated chemical disinfections when compared to microwaved specimens.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.12009DOI Listing

Publication Analysis

Top Keywords

surface microhardness
12
disinfection
8
acrylic resin
8
microwave energy
8
surface hardness
8
simulated chemical
8
room temperature
8
distilled water
8
third disinfection
8
tooth surface
8

Similar Publications

This study aimed to evaluate the impact of different manipulation methods and storage environments on the microstructural, chemical, and mechanical properties of calcium-enriched mixture (CEM) cement. Four sample groups were examined, including nondried (ND-I) and dried (D-I) groups placed directly in an incubator, dried samples stored in phosphate-buffered saline (PBS) (D-P), and dried samples stored in distilled water (D-W). Various analyses, including Vickers microhardness, compressive strength, Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) were conducted after incubating the samples for 7 days.

View Article and Find Full Text PDF

One area of technological advancement has been the shift from stainless steel hand tools to nickel-titanium (Ni-Ti) rotary tools. This paper aims to perform an in vitro comparative study to evaluate the efficacy of five endodontic manual and rotary instruments such as Kerr files, Orodeka Plex V, ProTaper Flydent NiTi super files, and ProTaper Flydent NiTi super files in combination with an ultrasonic endodontic E3D Diamantata EMS scaler used for root canal shaping. The following aspects were highlighted: effective removal of smear layer (SL) from the dentinal tubules in the coronal 1/3, middle 1/3, and apical 1/3 of the root canal, appearance of cracks in the dentinal walls by SEM analysis, and highlighting of dentin mineral content and remnant debris by EDX analysis.

View Article and Find Full Text PDF

Background: Due to their acidic nature, certain medications can have deleterious effects on tooth enamel. Fluoride is a popular method for reversing these effects. Therefore, this study aimed to assess the impact of acidic medications, specifically anti-asthmatic drugs and vitamin C tablets, on enamel surfaces and to investigate the effects of fluoride following drug exposure.

View Article and Find Full Text PDF

This study aims to evaluate the effects of the home bleaching method on the surface microhardness and surface roughness of both polished and unpolished CAD-CAM resin composite materials. A polymer-infiltrated ceramic network (PICN) block, Enamic (VE), along with four resin composite blocks (RCB) (Grandio [GN], Lava™ Ultimate [LV], BRILLIANT Crios [B], and Cerasmart [CS]), were prepared to dimensions of 14 mm × 12 mm × 2 mm and were categorized into unpolished and polished groups (n = 4). Microhardness measurements were conducted using a Vickers microhardness tester (300 gf load for 20 s) at various time points: before home bleaching, after home bleaching with 15% Opalescence for 8 h and for 56 h, 24 h after bleaching, and one month after bleaching.

View Article and Find Full Text PDF

Hardfacing is a welding-related technique aimed at depositing a harder and tougher layer onto a softer, less wear-resistant substrate or base metal. This process enhances the abrasion resistance of the component, increasing its durability under working conditions. A key feature of hardfacing is dilution, which refers to the mixing of the hardfacing layer and the base metal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!