Purpose: This survey was conducted to study the prevalence of partial edentulism, the type of removable partial denture (RPD) support, the type of major connectors, and the frequency of their use in relation to the partial edentulism classes encountered, concerning patients in Athens, Greece.

Materials And Methods: The material comprised 628 final casts for RPDs. Each cast was photographed in a way that would allow the number of existing teeth, the classification of partial edentulism, the RPD support, and the particular parts of the metal framework to be identified. Data collected were analyzed statistically using prevalence tables and the χ(2) test.

Results: Two hundred seventy six (43.9%) casts were for the maxilla and 352 (56.1%) for the mandible. The most frequently encountered group was Kennedy class I for both arches, while class IV was the classification least encountered (p < 0.001). Of all RPDs constructed, 96.8% had a metal framework (tooth-borne and tooth/tissue-borne), while 3.2% of the RPDs were frameless (tissue-borne, acrylic dentures). The U-shaped palatal connector (horseshoe) in the maxilla and the lingual bar in the mandible were the most frequently used for all partial edentulism classes, at 55.2% and 95%, respectively.

Conclusions: Analysis of the casts revealed that the type of major connectors selected does not comply with the indications for their applications, considering the lack of dental history and clinical examination. This notes the need for further training dentists and dental technicians in aspects of RPD framework design.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1532-849X.2012.00922.xDOI Listing

Publication Analysis

Top Keywords

partial edentulism
16
removable partial
8
partial denture
8
rpd support
8
type major
8
major connectors
8
edentulism classes
8
metal framework
8
mandible frequently
8
partial
6

Similar Publications

Light-polymerizing reline materials offer improved chairside workability compared to conventional auto-polymerizing reline materials, addressing the partial denture (RPD) incompatibility caused by residual ridge resorption owing to long-term use. This study evaluates the fitting accuracy of relined materials by combining conventional fitting tests with three-dimensional (3D) measurements for detailed analysis. Light-polymerizing reline material (HikariLiner, Tokuyama, Tokyo, Japan, LP) and auto-polymerizing material (Rebase III, Tokuyama, AP) were used.

View Article and Find Full Text PDF

The present article describes a step-by-step maximally digitalized workflow protocol with computer-aided design and computer-aided manufacturing (CAD/CAM) in partial-arch edentulous patients rehabilitated with fixed dental prostheses and removable partial dentures (FDPs and RPDs). Facial digitalization, intraoral scans, and functional mandibular movement recordings were used to create a 4D virtual patient on commercially available CAD software. The fixed components including post-and-cores, both metal-ceramic with extra-coronal attachment and monolithic zirconia crowns, and the RPDs were manufactured by computer numerical controlled direct milling.

View Article and Find Full Text PDF

Purpose: This pilot study evaluated and compared histomorphometric and immunohistochemical characteristics of peri-implant bone tissue after implant site preparation using piezoelectric tips versus conventional drills.

Material And Methods: Six patients with bilateral partial edentulism underwent a splitmouth protocol. Twelve alveolar ridges were randomized into six control implant sites prepared using conventional drills (Drill Group); and six test implant sites prepared using piezoelectric implant inserts (Piezo Group).

View Article and Find Full Text PDF

Background: Worn dentition is a common problem encountered by most people in the last decade. Rehabilitation of a full mouth needs individual attention and proper treatment planning, which is very challenging for partial edentulous cases where bilateral teeth are missing and collapsed vertical dimension leaves inadequate restorative space. Treatment of these cases is complex and needs to apply standard principles while designing and fabricating prostheses.

View Article and Find Full Text PDF

The influence of prosthetic treatments and implant-supported prostheses on posterior mandibular ridge atrophy: a retrospective cohort study.

BMC Oral Health

January 2025

Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, Graz, 8010, Austria.

Aims: Bone preservation is a requirement for long-term stability of dental prostheses, which is all the more important in the posterior mandible, given the particular challenges these areas pose to prosthetic treatment. The objective was to investigate the implications of different prostheses on the atrophy of posterior alveolar bone after tooth loss.

Materials And Methods: A total of 457 treatment cases were retrieved from the medical documentation and information network.

View Article and Find Full Text PDF