This study aimed to evaluate biomechanical behaviour of inclined orthodontic mini-implants by analyzing its insertion torque (IT), axial pull-out strength (APS), and cortical bone thickness in contact with mini-implant (CBTC). A total of 102 mini-implants were inserted at 90 degree, 60 degree, and 45 degree to the surface of synthetic bone. Peak IT was measured, and the mini-implants were aligned with the mechanical testing machine to record the APS. The cortical bone thickness in contact with each mini-implant was measured after the pull-out test and the data were subjected to statistical analyses. The 45 degree group had a significantly higher IT compared with the 90 degree group (P < 0.05). There was a statistically significant increase in the average of cortical bone thickness in CBTC across the three groups (P < 0.05). A negative correlation between the angulation and the CBTC (r = -0.95, P < 0.05) and a positive correlation between the APS and the CBTC were observed (r = 0.34, P < 0.05). Mini-implants that are inserted more inclined to the surface of the bone provide greater IT and an increased contact with the cortical bone. The greater the CBTC, the greater is the APS.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejo/cjs095DOI Listing

Publication Analysis

Top Keywords

cortical bone
20
bone thickness
16
thickness contact
12
insertion torque
8
pull-out strength
8
orthodontic mini-implants
8
aps cortical
8
contact mini-implant
8
mini-implants inserted
8
degree degree
8

Similar Publications

This study assessed the feasibility of miR17 ~ 92-based antiresorptive strategy by determining the effects of conditional transgenic (cTG) overexpression of miR17 ~ 92 in myeloid cells on bone and osteoclasts. Osteoclasts of male and female cTG mutant mice each showed 3- to fivefold overexpression of miR17 ~ 92 cluster genes compared to those of age- and sex-matched wildtype (WT) littermates. Male but not female cTG mutant mice had more trabecular and cortical bones as well as lower bone resorption reflected by reduction in osteoclast number and resorbing surface.

View Article and Find Full Text PDF

This review summarizes the mechanism and role of physical activity in maintaining the proper functioning of the musculoskeletal system. Bone adaptation to the mechanical environment occurs in skeletal regions subjected to the greatest stresses resulting from the nature of exercise, however, there is a varied response of bone tissue to mechanical loads depending on its material and structural properties (trabecular and cortical). The regulation of bone tissue metabolism during physical exercise is influenced by factors associated with mechanical stress (gravitational forces, impact loading, and muscular contractions) as well as by systemic mechanisms (hormones, myokines, cytokines).

View Article and Find Full Text PDF

Patients with radiographic axial spondyloarthritis (r-axSpA) experience a higher prevalence of fragility fractures, though the pathophysiology of osteoporosis associated with this disease remains poorly understood. The objective of this study was to evaluate the histomorphometric data in r-axSpA patients. Male r-axSpA patients up to 55 years old were enrolled in this cross-sectional study.

View Article and Find Full Text PDF

Osteogenesis imperfecta (OI) is an inheritable skeletal disorder characterized by bone fragility often caused by pathogenic variants in the COL1A1 gene. Current OI mouse models with a glycine substitution in Col1a1 exhibit excessive severity, thereby limiting long-term pathophysiological analysis and drug effect assessments. To address this limitation, we constructed a novel OI mouse model mimicking a patient with OI type III.

View Article and Find Full Text PDF

Background: Endodontic file fractures are common complications of root canal treatment, and requires removal via specialized techniques such as endodontic microsurgery when the file beyond the apical foramen. It is often challenging to precisely and minimally remove a fractured file. Recently the use of dental autonomous robotic system (ATR) has shown promise in precisely and minimally in dental surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!