Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Conventional photodynamic diagnosis (PDD) and therapy (PDT) makes use of photosensitizers that are excited by continuous light irradiation of specific wavelengths. In the case of PDT, the overdose of continuous excitation may lead to an expansion of necrosis in cancer cells or morbidity in healthy surroundings. The present study involves 5-h fluorescence imaging of living human lung epithelial carcinoma cells (A549) in the presence of a novel photosensitizer, PVP-Hypericin (PVP: polyvinylpyrrolidone) to optimize the excitation light doses for PDD and PDT. A number of time-lapse imaging experiments were performed using a low-power blue LED operating in either continuous or pulsed mode. The irradiances I(*) were 1.59, 6.34 and 14.27mW/cm(2), the pulse lengths L being 0.127, 1.29, 13, 54.5, 131 and 60,000ms. Then, the relation between irradiance, various exposure times, photobleaching and phototoxicity of PVP-Hyperycin was investigated. Results showed a nonlinear relationship between the amounts of excitation dose, cell viability and toxicity. For all experimental I(*), minimal phototoxicity and photobleaching was detected when cells were exposed to brief pulses of light (L⩽13ms). On the other hand, pulsed excitation with I(*)=14.27mW/cm(2) and L=131ms induced high percentages of apoptosis comparable to the long exposures of L=60,000ms and the continuous excitation. Thus, replacement of continuous excitation by a pulsed method seems applicable for PDT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jphotobiol.2012.12.013 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!