A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Modifying excitation light dose of novel photosensitizer PVP-Hypericin for photodynamic diagnosis and therapy. | LitMetric

Modifying excitation light dose of novel photosensitizer PVP-Hypericin for photodynamic diagnosis and therapy.

J Photochem Photobiol B

University of Vienna, Faculty of Physics, Physics of Physiological Processes, Boltzmanng. 5, A-1090 Vienna, Austria.

Published: March 2013

Conventional photodynamic diagnosis (PDD) and therapy (PDT) makes use of photosensitizers that are excited by continuous light irradiation of specific wavelengths. In the case of PDT, the overdose of continuous excitation may lead to an expansion of necrosis in cancer cells or morbidity in healthy surroundings. The present study involves 5-h fluorescence imaging of living human lung epithelial carcinoma cells (A549) in the presence of a novel photosensitizer, PVP-Hypericin (PVP: polyvinylpyrrolidone) to optimize the excitation light doses for PDD and PDT. A number of time-lapse imaging experiments were performed using a low-power blue LED operating in either continuous or pulsed mode. The irradiances I(*) were 1.59, 6.34 and 14.27mW/cm(2), the pulse lengths L being 0.127, 1.29, 13, 54.5, 131 and 60,000ms. Then, the relation between irradiance, various exposure times, photobleaching and phototoxicity of PVP-Hyperycin was investigated. Results showed a nonlinear relationship between the amounts of excitation dose, cell viability and toxicity. For all experimental I(*), minimal phototoxicity and photobleaching was detected when cells were exposed to brief pulses of light (L⩽13ms). On the other hand, pulsed excitation with I(*)=14.27mW/cm(2) and L=131ms induced high percentages of apoptosis comparable to the long exposures of L=60,000ms and the continuous excitation. Thus, replacement of continuous excitation by a pulsed method seems applicable for PDT.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jphotobiol.2012.12.013DOI Listing

Publication Analysis

Top Keywords

continuous excitation
12
excitation light
8
novel photosensitizer
8
photosensitizer pvp-hypericin
8
photodynamic diagnosis
8
excitation
6
continuous
5
modifying excitation
4
light
4
light dose
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!