The presence of radial arterial lines may diminish distal digital perfusion. Using a pair of pulse oximeters on the index fingers of cannulated and noncannulated arms the saturation and oximeter pulse strength were assessed. Three hundred paired measurements in fifty consecutive Intensive Care patients were undertaken more than two hours after cannula insertion. The pulse strength was 19.7 (SD 6.1) and 19.7 (SD 5.7) on the cannulated and noncannulated sides while the saturation was 97.3 (SD 2.3) and 97.1 (SD 2.4) respectively. These differences are not clinically important and the study demonstrates that reliable pulse oximetry measurements may be made distal to a radial artery cannula. It is recommended that in each individual the placement of the sensor be such as to ensure the best signal and the most stable saturation readings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0310057X9001800117 | DOI Listing |
J Med Case Rep
January 2025
Bone and Joint Diseases Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
Background: Management of the extensive soft tissue injuries remains a significant challenge in orthopedic and plastic reconstructive surgery. Since the thumb is responsible for 40% of the functions of the hand, saving and reconstructing a mangled thumb is essential for the patient's future.
Case Presentation: This case report describes the management of a severe occupational thumb injury in a 25-year-old white Persian male who sustained an occupational injury to his left thumb, resulting in extensive burn, crush injury to the distal and proximal phalanx, and severe soft tissue damage to the first metacarpal, thenar, and palmar areas.
Indian Heart J
January 2025
Department of Cardiology, Sri Jayadeva Institute of Cardiovascular Sciences and Research, Bangalore, India.
Background: Cardiac catheterization via the trans-radial approach (TRA) has shown several advantages over the trans-femoral approach (TFA) but with a concern of higher radiation exposure. Considering the growing experience with TRA, this study compares patient's radiation during coronary angiography using TRA versus TFA.
Methods: This study included consecutive patients undergoing coronary angiogram over a year at tertiary hospital performed by experienced operators through radial or femoral access.
Br J Anaesth
January 2025
Faculté de Médecine Paris-Saclay, Université Paris-Saclay, Le Kremlin-Bicêtre, Paris, France.
Ann Vasc Surg
January 2025
Department of Surgery, University Hospital Centre Zagreb, Zagreb, Croatia.
Objectives: Brachial artery injury due to displaced supracondylar fracture (SC) of the humerus in children may present with pink pulseless hand (PPH), denoting a well perfused hand without radial pulse, or acute hand ischemia. Some reports state that brachial artery reconstruction is not necessary in children with persisting PPH, but the reports on long-term consequences such as intermittent claudications, growth retardation and ischemic contracture in children with pulseless hand are scarce and often misinterpreted. The objective of our analysis was to assess the long-term outcomes of children with brachial artery injury associated with SC fracture.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Hand Surgery, Private Clinic, Gaziantep 27060, Turkey.
: This study aimed to compare two surgical techniques-the free flap of the superficial palmar branch of the radial artery (SPBRA) and the free venous flap (FVF)-to evaluate their efficacy and aesthetic outcomes in repairing finger tissue defects. The goal was to determine which procedure offers faster healing curves and better overall patient outcomes, ultimately improving the quality of life for individuals undergoing these surgeries. : A retrospective study was conducted using the clinical database of Sanliurfa Mehmet Akif Inan Education and Research Hospital, University of Health Sciences, from 1 January 2019 to 1 January 2022.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!