Precise timing resolution is crucial for applications requiring photon time-of-flight (ToF) information such as ToF positron emission tomography (PET). Silicon photomultipliers (SiPM) for PET, with their high output capacitance, are known to require custom preamplifiers to optimize timing performance. In this paper, we describe simple alternative front-end electronics based on a commercial low-noise RF preamplifier and methods that have been implemented to achieve excellent timing resolution. Two radiation detectors with L(Y)SO scintillators coupled to Hamamatsu SiPMs (MPPC S10362-33-050C) and front-end electronics based on an RF amplifier (MAR-3SM+), typically used for wireless applications that require minimal additional circuitry, have been fabricated. These detectors were used to detect annihilation photons from a Ge-68 source and the output signals were subsequently digitized by a high speed oscilloscope for offline processing. A coincident resolving time (CRT) of 147 ± 3 ps FWHM and 186 ± 3 ps FWHM with 3 × 3 × 5 mm(3) and with 3 × 3 × 20 mm(3) LYSO crystal elements were measured, respectively. With smaller 2 × 2 × 3 mm(3) LSO crystals, a CRT of 125 ± 2 ps FWHM was achieved with slight improvement to 121 ± 3 ps at a lower temperature (15° C). Finally, with the 20 mm length crystals, a degradation of timing resolution was observed for annihilation photon interactions that occur close to the photosensor compared to shallow depth-of-interaction (DOI). We conclude that commercial RF amplifiers optimized for noise, besides their ease of use, can produce excellent timing resolution comparable to best reported values acquired with custom readout electronics. On the other hand, as timing performance degrades with increasing photon DOI, a head-on detector configuration will produce better CRT than a side-irradiated setup for longer crystals.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3675904 | PMC |
http://dx.doi.org/10.1088/0031-9155/58/4/1207 | DOI Listing |
eNeuro
January 2025
University of Kassel, 34132 Kassel, Germany.
Evolutionary pressures adapted insect chemosensation to the respective insect's physiological needs and tasks in their ecological niches. Solitary nocturnal moths rely on their acute olfactory sense to find mates at night. Pheromones are detected with maximized sensitivity and high temporal resolution through mechanisms that are mostly unknown.
View Article and Find Full Text PDFJ Comput Assist Tomogr
January 2025
Department of Radiology, University of Yamanashi, Chuo, Yamanashi.
Objective: This study aims to identify factors associated with the detectability of the right adrenal vein (RAV) on preoperative contrast-enhanced CT scans of adrenal venous sampling (AVS) in the era of high-resolution CT (HRCT).
Materials And Methods: In this retrospective study, 36 patients (15 men and 21 women; mean age, 56 y) who underwent preoperative contrast-enhanced CT [11 patients in HRCT with 0.25 mm detector matrix (Cannon Medical Systems) and 25 patients in conventional multidetector CT with 0.
Sci Rep
January 2025
Space Science Division, Korea Astronomy and Space Science Institute, Daejeon, 34055, Republic of Korea.
This paper reports the proton response function for solution-grown trans-stilbene scintillator from 1 to 25 MeVee and its application for unfolding neutron spectra of Cf-252 and AmBe sources. Low energy proton response was measured by the Time-of-Flight technique at the Korea Research Institute of Standards and Science. In contrast, high energy response was investigated using a 45 MeV proton beam at the Korea Institute of Radiological & Medical Sciences.
View Article and Find Full Text PDFWorld J Hepatol
January 2025
Department of Surgery, Pham Ngoc Thach University of Medicine, Ho Chi Minh 07000, Viet Nam.
Background: Hepatic eosinophilic pseudotumor (HEPT) is a rare condition that mimics malignant hepatic tumors, posing significant diagnostic challenges. This case report highlights the importance of considering parasitic infections like () in the differential diagnosis of hepatic masses, especially in endemic regions, to prevent unnecessary interventions.
Case Summary: A 40-year-old female presented with a 1-month history of epigastric pain and significant weight loss.
Interv Neuroradiol
January 2025
Department on Stroke Medicine and Vascular Neurology, North Bristol NHS Trust, Bristol, UK.
Background: Early identification and quantification of core infarct is of importance in stroke management for treatment selection, prognostication, and complication prediction. Non-contrast computed tomography (CT) (NCCT) remains the primary tool, but it suffers from limited sensitivity and inter-rater variability; CT perfusion is inconsistently available and commonly blighted by movement artefact. We assessed the performance of a standardised form of CT angiographic source imaging (CTASI) obtained through addition of a delayed phase at 40 seconds post-contrast injection (DP40) following fast-acquisition CT angiography.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!