The aims of the present study were to assess the reliability of clavicular tilt angle measurement using goniometric and photographic measurements and to test the validity of the measurement by comparing the results with radiographic findings (gold standard). Clavicular tilt angles were measured in 18 healthy subjects (36 clavicles) using goniometric, photographic, and radiographic measurement. Repeated measurements using goniometric and photographic measurements were made in two test sessions conducted on different days by two examiners to assess inter-rater and intra-rater reliability of the two methods. Radiographic measurement was taken once, and the correlation between the radiographic findings and those of the indirect methods was calculated to test the validity of the goniometric and photographic measurement of clavicular tilt angle. No significant difference in clavicular tilt angle measurement was found between test sessions. The reliability of goniometric measurement (inter-rater intraclass correlation coefficients (ICC) = 0.85 (95% CI = 0.72-0.92) - 0.87 (95% CI = 0.77-0.87); intra-rater ICC = 0.80 (95% CI = 0.64-0.89)) and photographic measurement (inter-rater ICC = 0.89 (95% CI = 0.80-0.94) - 0.95 (95% CI = 0.91-0.98); intra-rater ICC = 0.84 (95% CI = 0.71-0.92) - 0.84 (95% CI = 0.69-0.91)) were excellent. The goniometric and photographic measurements of clavicular tilt angle were highly correlated with the radiographic findings (r = 0.83, 0.78, respectively). Goniometric and photographic measurements of clavicular tilt angle obtained by raters in this study may be considered reliable, and data obtained using the goniometric and photographic measurements are representative of radiographic findings of clavicular tilt angle.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.math.2012.12.006 | DOI Listing |
J Hand Ther
August 2024
Department of Orthopedics and Traumatology, Faculty of Medicine, Baskent University, Ankara, Turkey.
Background: Various virtual goniometers have been used for photographic measurements. However, there is no single method that is both reliable and valid for measuring the forearm, wrist, and finger joints.
Purpose: This study aimed to investigate the criterion validity and intra- and inter-rater reliability of a virtual goniometer for assessing forearm, wrist, and finger joints using screenshots from video recordings and to calculate the standard error of measurement (SEM) and minimum detectable change (MDC).
J Hand Surg Eur Vol
June 2024
Department of Orthopedic Surgery, Pontchaillou University Hospital, Rennes, France.
Although goniometric measurement is considered the gold standard for the measurement of digital range of motion, visual estimation is often employed due to its simplicity despite being inconsistent with recommended guidelines. We evaluated the Rennes Universal Measurement Method, an innovative tool employing artificial intelligence to concurrently analyse hand joint angles based on a single photograph. We found a strong correlation between the goniometric method and the photograph-based approach (Spearman correlation coefficient 0.
View Article and Find Full Text PDFR I Med J (2013)
October 2022
Department of Orthopaedic Surgery, Warren Alpert Medical School of Brown University, Providence, RI.
Introduction: The purpose of this study was to evaluate the accuracy of visual joint angle assessments by orthopaedic surgery trainees amongst various levels of training.
Methods: Sagittal plane photographs of several joints at various angles were distributed to trainees within an orthopaedic residency program. Joint angles were estimated and compared to those obtained with a goniometer.
J Sex Med
January 2021
Visual Computing Lab, Institute of Information Science and Technologies, National Research Council of Italy, Pisa, Italy.
Background: Peyronie's disease is an idiopathic fibrotic disease affecting the penile tunica albuginea. Among other resulting deformities, the more common penile curvature should be assessed preferentially with in-office goniometric estimation after pharmacologically induced erection, although clearly invasive and uncomfortable.
Aim: In the present pilot study, we investigated the usefulness for the patient and the surgeon of a 3-dimensional (3D) reconstruction of the penile curvature obtained through photogrammetry software in clinical evaluation and surgical planning.
Stud Health Technol Inform
June 2020
Department of Physiotherapy, School of Health Sciences, HES-SO//University of Applied Sciences and Arts Western Switzerland, Geneva, Switzerland.
The aim of this study was to investigate the validity and reliability of range of motion measurement via smartphone applications. This literature review included 26 articles after the selection process. The validity and reliability analysis showed good mean results (ICC or r >0.