A multiresolution analysis for detection of abnormal lung sounds.

Annu Int Conf IEEE Eng Med Biol Soc

Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA.

Published: August 2013

Automated analysis and detection of abnormal lung sound patterns has great potential for improving access to standardized diagnosis of pulmonary diseases, especially in low-resource settings. In the current study, we develop signal processing tools for analysis of paediatric auscultations recorded under non-ideal noisy conditions. The proposed model is based on a biomimetic multi-resolution analysis of the spectro-temporal modulation details in lung sounds. The methodology provides a detailed description of joint spectral and temporal variations in the signal and proves to be more robust than frequency-based techniques in distinguishing crackles and wheezes from normal breathing sounds.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4087194PMC
http://dx.doi.org/10.1109/EMBC.2012.6346630DOI Listing

Publication Analysis

Top Keywords

analysis detection
8
detection abnormal
8
abnormal lung
8
lung sounds
8
multiresolution analysis
4
sounds automated
4
automated analysis
4
lung sound
4
sound patterns
4
patterns great
4

Similar Publications

Gestational diabetes mellitus (GDM) is a metabolic disorder that arises during pregnancy and heightens the risk of placental dysplasia. Ginsenoside Re (Re) may stabilize insulin and glucagon to regulate glucose levels, which may improve diabetes-associated diseases. This study aims to investigate the mechanism of Re in high glucose (HG)-induced apoptosis of trophoblasts through endoplasmic reticulum stress (ERS)-related protein CHOP/GADD153.

View Article and Find Full Text PDF

This systematic review and meta-analysis aimed to assess the accuracy and success rate of ultrasound in determining fetal sex. A search was conducted on Medline, Cochrane Library, and EMBASE databases, and the reference lists of selected studies were also reviewed. Meta-analyses were performed using Revman 5.

View Article and Find Full Text PDF

Purpose: While surgeons agree that perioperative field blocks should be performed for open inguinal hernia surgery, there lacks consensus in the minimally invasive context. Prior small-scale randomized trials study pain scores only up to 24 h postoperatively. Thus, we sought to investigate the analgesic benefits of a bupivacaine transversus abdominis plane (TAP) block in the first 4 postoperative days.

View Article and Find Full Text PDF

Construction of single probes for simultaneous detection of common trivalent metal ions has attracted much attention due to higher efficiency in analysis and cost. A naphthalimide-based fluorescent probe K1 was synthesized for selective detection of Al, Cr and Fe ions. Fluorescence emission intensity at 534 nm of probe K1 in DMSO/HO (9:1, v/v) was significantly enhanced upon addition of Al, Cr and Fe ions while addition of other metal ions (Li, Na, K, Ag, Cu, Fe, Zn, Co, Ni, Mn, Sr, Hg, Ca, Mg, Ce, Bi and Au) did not bring about substantial change in fluorescence emission.

View Article and Find Full Text PDF

A fluorescence "turn-off-on" nanoprobe is designed by using europium-doped strontium molybdate perovskite quantum dots (Eu:SMO PQDs) for the sequential detection of hypoxanthine (Hx) and Fe. The Eu:SMO PQDs were prepared by the sol-gel method using Sr(NO), (NH)MoO.4HO, and Eu(OCOCH) as precursors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!