A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of heart rate extraction using video imaging on a built-in camera system of a smartphone. | LitMetric

Validation of heart rate extraction using video imaging on a built-in camera system of a smartphone.

Annu Int Conf IEEE Eng Med Biol Soc

Interdisciplinary Program of Bioengineering, Seoul National University, Seoul, Korea.

Published: August 2013

As a smartphone is becoming very popular and its performance is being improved fast, a smartphone shows its potential as a low-cost physiological measurement solution which is accurate and can be used beyond the clinical environment. Because cardiac pulse leads the subtle color change of a skin, a pulsatile signal which can be described as photoplethysmographic (PPG) signal can be measured through recording facial video using a digital camera. In this paper, we explore the potential that the reliable heart rate can be measured remotely by the facial video recorded using smartphone camera. First, using the front facing-camera of a smartphone, facial video was recorded. We detected facial region on the image of each frame using face detection, and yielded the raw trace signal from the green channel of the image. To extract more accurate cardiac pulse signal, we applied independent component analysis (ICA) to the raw trace signal. The heart rate was extracted using frequency analysis of the raw trace signal and the analyzed signal from ICA. The accuracy of the estimated heart rate was evaluated by comparing with the heart rate from reference electrocardiogram (ECG) signal. Finally, we developed FaceBEAT, an iPhone application for remote heart rate measurement, based on this study.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2012.6346392DOI Listing

Publication Analysis

Top Keywords

heart rate
24
facial video
12
raw trace
12
trace signal
12
cardiac pulse
8
signal
8
video recorded
8
rate
6
smartphone
5
heart
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!