Microbubbles form their aggregations between the neighboring microbubbles by the effect of secondary Bjerknes force under ultrasound exposure. However, because of the difficulty to reproduce a capillary-mimicking artificial blood vessel, the behavior of aggregations in a capillary has not been predicted. Thus we prepared artificial blood vessels including a capillary model, which was made of poly(vinyl alcohol) (PVA) by grayscale lithography method, with minimum diameter of the path of 0.5 mm. By using this model we investigated the possibility of artificial embolization, where the microbubble aggregations might block entire vessels not to penetrate flow in downstream. Confirming that the sizes of flown aggregation were greater than the section area of the minimum path in the capillary model, we investigated the probability of path block in it. As the results we confirmed the probability increased in proportion to sound pressure and inversely to flow velocity. We are going to investigate with more kinds of parameters to enhance the possibility of artificial embolization.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2012.6346365DOI Listing

Publication Analysis

Top Keywords

artificial blood
12
blood vessel
8
microbubble aggregations
8
capillary model
8
model investigated
8
possibility artificial
8
artificial embolization
8
artificial
5
observation flow
4
flow variation
4

Similar Publications

Deep venous thrombosis (DVT) represents a significant postoperative complication after artificial femoral head replacement, with the incidence increasing proportionally with patient age. This study aimed to evaluate the effect of early postoperative use of intermittent pneumatic compression devices (IPC), followed by the combined use of low molecular weight heparin (LMWH) after 48 hours, for the prevention of postoperative lower limb DVT in elderly patients undergoing hip arthroplasty. The retrospective study included 100 elderly patients who underwent unilateral femoral head replacement.

View Article and Find Full Text PDF

Curcumin and hesperetin are plant polyphenols known for their poor solubility. To address this limitation, we prepared amorphous PVP K30-phosphatidylcholine dispersions via hot-melt extrusion. This study aimed to evaluate the effects of the amounts of active ingredients and phosphatidylcholine, as well as the process temperature, on the performance of the dispersions.

View Article and Find Full Text PDF

An original design of a simple bioreactor was used to fabricate two tubular, 200 cm long BC structures by culturing B-11267 on a molasses medium. In addition, a tubular BC-based biocomposite with improved mechanical properties was obtained by combining cultivation on the molasses medium with in situ chemical modification by polyvinyl alcohol (PVA). Moreover, the present study investigated the BC production by the B-11267 strain on the media with different molasses concentrations under agitated culture conditions.

View Article and Find Full Text PDF

Semen analysis is universally regarded as the gold standard for diagnosing male infertility, while ultrasonography plays a vital role as a complementary diagnostic tool. This study aims to assess the effectiveness of artificial intelligence (AI)-driven deep learning algorithms in predicting semen analysis parameters based on testicular ultrasonography images. This study included male patients aged 18-54 who sought evaluation for infertility at the Urology Outpatient Clinic of our hospital between February 2022 and April 2023.

View Article and Find Full Text PDF

: This study focuses on the critical task of blood vessel segmentation in medical image analysis, essential for diagnosing cardiovascular diseases and enabling effective treatment planning. Although deep learning architectures often produce very high segmentation results in medical images, coronary computed tomography angiography (CTA) images are more challenging than invasive coronary angiography (ICA) images due to noise and the complexity of vessel structures. : Classical architectures for medical images, such as U-Net, achieve only moderate accuracy, with an average Dice score of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!