New approaches to bridge nerve gaps: development of a novel drug-delivering nerve conduit.

Annu Int Conf IEEE Eng Med Biol Soc

Department of Mechanical Engineering, University of Utah, Salt Lake City, UT 84112, USA.

Published: September 2013

Contemporary bridging techniques for repairing nerve gaps caused by trauma require autologous nerve grafts, which are difficult to harvest and handle and result in significant donor site deficit. Several nerve conduits with axon growth-enhancing potential have been proposed, developed and tested over the past fifteen years. In this work, prototypes of a nerve conduit designed to bridge large nerve gaps (≥10mm) end-to-end were incorporated with concentric drug reservoirs for constant and controlled drug delivery to enhance axon growth. These devices were designed, fabricated and tested in vitro in amber glass vials with bovine serum albumin in order to determine the drug release kinetics for future application. Our devices have shown the capability to deliver the drug of interest over a 6-day period.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2012.6346039DOI Listing

Publication Analysis

Top Keywords

nerve gaps
12
nerve conduit
8
nerve
7
approaches bridge
4
bridge nerve
4
gaps development
4
development novel
4
novel drug-delivering
4
drug-delivering nerve
4
conduit contemporary
4

Similar Publications

Carpal Tunnel Syndrome (CTS) is a prevalent neuropathic disorder caused by chronic compression of the median nerve, leading to sensory and motor impairments. Conventional treatments, such as corticosteroid injections, wrist splinting, and surgical decompression, often fail to provide adequate outcomes for chronic or recurrent cases, emphasizing the need for innovative therapies. Hydrogels, highly biocompatible three-dimensional biomaterials with customizable properties, hold significant potential for CTS management.

View Article and Find Full Text PDF

Nervus Intermedius Neuralgia.

Curr Pain Headache Rep

January 2025

Department of Neurology, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA.

Purpose Of Review: This review discusses the diagnosis and treatment of nervus intermedius neuralgia (NIN) and identifies gaps in the literature.

Recent Findings: The nervus intermedius is a branch of the facial nerve. NIN presents as a rare neuralgia of this nerve, causing deep ear pain, which may radiate to the auditory canal, auricle, mastoid, soft palate, temple, and angle of the jaw.

View Article and Find Full Text PDF

Next generation bioelectronic medicine: making the case for non-invasive closed-loop autonomic neuromodulation.

Bioelectron Med

January 2025

SecondWave Systems Incorporated, Head Quarters, Minneapolis-Saint Paul, MN, 55104, USA.

The field of bioelectronic medicine has advanced rapidly from rudimentary electrical therapies to cutting-edge closed-loop systems that integrate real-time physiological monitoring with adaptive neuromodulation. Early innovations, such as cardiac pacemakers and deep brain stimulation, paved the way for these sophisticated technologies. This review traces the historical and technological progression of bioelectronic medicine, culminating in the emerging potential of closed-loop devices for multiple disorders of the brain and body.

View Article and Find Full Text PDF

Neuropathology has been in existence as a speciality in India since the 1950s. Its practice has kept pace with the developments in the field, paralleling advancements in neurosurgery and neurosciences, especially in tertiary care centres. This nationwide survey, conducted across 52 centres, provides a comprehensive analysis of diagnostic infrastructure, training opportunities, and challenges in the practice of neuropathology.

View Article and Find Full Text PDF

Background: A novel contact force (CF) sensing catheter with a mesh-shaped irrigation tip (TactiFlexTM SE, Abbott), is expected to provide safe and effective radiofrequency ablation. Our previous study revealed that the TactiFlex catheter needs a higher power for pulmonary vein isolation (PVI) due to the long tip length. This study aimed to examine the feasibility and safety of a 50 W ablation with the TactiFlex for PVI of atrial fibrillation (AF).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!