Haemodynamic forces have a synergistic effect on endothelial cell (EC) morphology, proliferation, differentiation and biochemical expression profiles. Alterations to haemodynamic force levels have been observed at curved regions and bifurcations of arteries but also around struts of stented arteries, and are also known to be associated with various vascular pathologies. Therefore, curvature in combination with stenting might create a pro-atherosclerotic environment compared with stenting in a straight vessel, but this has never been investigated. The goal of this study was to compare EC morphology, proliferation and differentiation within in vitro models of curved stented peripheral vessel models with those of straight and unstented vessels. These models were generated using both static conditions and also subjected to 24 h of stimulation in a peripheral artery bioreactor. Medical-grade silicone tubes were seeded with human umbilical vein endothelial cells to produce pseudovessels that were then stented and subjected to 24 h of physiological levels of pulsatile pressure, radial distention and shear stress. Changes in cell number, orientation and nitric oxide (NO) production were assessed in straight, curved, non-stented and stented pseudovessels. We report that curved pseudovessels lead to higher EC numbers with random orientation and lower NO production per cell compared with straight pseudovessels after 24 h of biomechanical stimulation. Both stented curved and stented straight pseudovessels had lower NO production per cell than corresponding unstented pseudovessels. However, in contrast to straight stented pseudovessels, curved stented pseudovessels had fewer viable cells. The results of this study show, for the first time, that the response of the vascular endothelium is dependent on both curvature and stenting combined, and highlight the necessity for future investigations of the effects of curvature in combination with stenting to fully understand effects on the endothelial layer.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3627103PMC
http://dx.doi.org/10.1098/rsif.2012.0965DOI Listing

Publication Analysis

Top Keywords

curved stented
12
stented pseudovessels
12
endothelial cell
8
straight curved
8
peripheral artery
8
morphology proliferation
8
proliferation differentiation
8
stented
8
curvature combination
8
combination stenting
8

Similar Publications

A 42 year old Afro-Caribbean man underwent Baerveldt Glaucoma Implant (BGI) surgery for silicone oil induced glaucoma. Three months following initial surgery, the 3-0 prolene ripcord suture was removed. Anterior segment OCT demonstrates the position of the intracameral portion of the tube before and after the 3/0 prolene stent suture (PSS) removal.

View Article and Find Full Text PDF

The objective of this research is to analyze the hemodynamic differences in five configurations of left subclavian artery (LSA) stent grafts after LSA endovascular reconstruction in thoracic endovascular aortic repair (TEVAR). For numerical simulation, one three-dimensional thoracic aortic geometry model with an LSA stent graft retrograde curved orientation was reconstructed from post-TEVAR computed tomography angiography (CTA) images, and four potential LSA graft configurations were modified and reconstructed: three straight (0, 2, and 10 mm aortic extension) and one anterograde configuration. The blood perfusion of the LSA, flow field, and hemodynamic wall parameters were analyzed.

View Article and Find Full Text PDF

This study aimed to evaluate the incidence, risk factors, clinical implications, and rescue maneuvers of technical complications related to embolic protection devices (EPDs) during carotid artery stenting (CAS). We retrospectively reviewed all patients who had undergone CAS with EPDs between April 2018 and March 2024. The incidence and types of technical complication associated with EPDs were assessed.

View Article and Find Full Text PDF
Article Synopsis
  • Mechanical thrombectomy is beneficial for treating acute ischemic stroke, but complications like subarachnoid hemorrhage (SAH) can negatively affect recovery; this study explores how stent retrievers' frictional forces might contribute to such complications.
  • In an experiment using a silicone model of the middle cerebral artery, researchers tested different vessel sizes and angles to measure the frictional forces when deploying and retracting a stent retriever, noting various deployment positions.
  • Results showed that smaller vessel diameters, sharp curvatures, and distal stent placements significantly increased frictional forces, suggesting that careful selection of stent sizes and deployment strategies may help reduce the risk of vascular stress and SAH.
View Article and Find Full Text PDF

Background: Poly-L-lactic acid (PLLA) is one of the representative polymeric materials serving as bioresorbable stents (BRS) for cardiovascular disease due to its proper biodegradation, high biocompatibility, and adequate mechanical properties among polymer candidates for BRS. However, PLLA BRS as cardiovascular stents also have limitations because their mechanical properties including low radial strength and high elastic recoil are inferior to those of metallic-based BRS stents.

Methods: In the study, we developed and manufactured distinct and novel types of stent geometries for investigating mechanical properties of thin-walled PLLA BRS (110 μm) for cardiovascular applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!