A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a real-time polymerase chain reaction assay for sensitive detection and quantitation of Babesia microti infection. | LitMetric

Development of a real-time polymerase chain reaction assay for sensitive detection and quantitation of Babesia microti infection.

Transfusion

Blood Systems Research Institute, San Francisco, California; Yale School of Public Health and Yale School of Medicine, New Haven, Connecticut; Tufts University Cummings School of Veterinary Medicine, North Grafton, Massachusetts; Nantucket Cottage Hospital, Nantucket, Massachusetts.

Published: October 2013

Background: Babesia microti, the most frequently implicated pathogen in transfusion-transmitted babesiosis, is widely endemic in the Northeast and upper Midwestern United States. High seroprevalence in endemic areas limits antibody-based donor screening. A high-performance molecular test is needed to identify donors in the preseroconversion window phase as well as to discriminate past serologic exposure with parasite clearance from continued parasitemia.

Study Design And Methods: Frozen Babesia-spiked whole blood was microcentrifuged, and the supernatant transferred and microcentrifuged again to concentrate the parasite. The DNA was extracted and amplified using real-time polymerase chain reaction (PCR) using Babesia-specific primers. The assay was employed in three series of experiments: 1) a validation and optimization spiking experiment, 2) a blinded serial dilution probit analysis to determine the limit of detection, and 3) evaluation of two blinded panels of clinical samples from possible babesiosis cases.

Results: At a decreasing inoculum of 445, 44.5, and 4.45 copies/mL, the assay had positive rates of 100, 97.5, and 81%, respectively. The blinded probit analysis demonstrated a detection rate of 95 and 50% at 12.92 and 1.52 parasites/2 mL of whole blood, respectively. Evaluation of clinical samples showed 13 of 21 samples to be positive, with a range of 85 to 4.8 million parasites/mL. There were no positives detected among 48 healthy donors

Conclusion: We have developed a highly sensitive and specific, quantitative real-time PCR-based assay for detection of B. microti that could have a useful role in blood screening. It can also be employed broadly to understand Babesia epidemiology, disease pathogenesis, and host immunology.

Download full-text PDF

Source
http://dx.doi.org/10.1111/trf.12098DOI Listing

Publication Analysis

Top Keywords

real-time polymerase
8
polymerase chain
8
chain reaction
8
babesia microti
8
probit analysis
8
clinical samples
8
445 445
8
development real-time
4
assay
4
reaction assay
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!