This study compared moisture vapour transmission rate (MVTR) and wear time or fluid-handling capacities of six adhesive foam dressings to a reformulated control dressing. Standardised in vitro MVTR methodology and a previously published in vivo artificial wound model (AWM) were used. Mean inverted MVTR for the reformulated dressing was 12 750 g/m(2) /24 hours and was significantly higher than four of the six comparator dressings (P < 0·0001), which ranged from 830 to 11 360 g/m(2) /24 hours. Mean upright MVTR for the reformulated dressing was 980 g/m(2) /24 hours and was significantly different than all of the comparator dressings (P < 0·0001), which ranged from 80 to 1620 g/m(2) /24 hours (three higher/three lower). The reformulated dressing median wear time ranged from 6·1 to >7·0 days, compared with 1·0 to 3·5 days for the comparator dressings (P = 0·0012 to P < 0·0001). The median fluid volume handled ranged from 78·0 to >87 ml compared with 13·0 to 44·5 ml for the comparator dressings (P = 0·0007 to P < 0·001). Interestingly, inverted MVTR did not correspond well to the AWM. These results suggest that marked differences exist between the dressings in terms of both MVTR and wear time or fluid-handling capacity. Furthermore, high inverted MVTR does not necessarily predict longer wear time or fluid-handling capacities of absorbent dressings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7951035PMC
http://dx.doi.org/10.1111/iwj.12030DOI Listing

Publication Analysis

Top Keywords

wear time
16
g/m2 /24
16
/24 hours
16
comparator dressings
16
adhesive foam
12
time fluid-handling
12
inverted mvtr
12
reformulated dressing
12
moisture vapour
8
vapour transmission
8

Similar Publications

Background/purpose: Artificial intelligence (AI) can assist in medical diagnosis owing to its high accuracy and efficiency. This study aimed to develop a diagnostic system for automatically determining the degree of tooth wear (TW) using intraoral photographs with deep learning.

Materials And Methods: The study included 388 intraoral photographs.

View Article and Find Full Text PDF

Seizure detection devices (SDDs) offer promising technological advancements in epilepsy management, providing real-time seizure monitoring and alerts for patients and caregivers. This critical review explores user perspectives and experiences with SDDs to better understand factors influencing their adoption and sustained use. An electronic literature search identified 34 relevant studies addressing common themes such as usability, motivation, comfort, accuracy, barriers, and the financial burden of these devices.

View Article and Find Full Text PDF

Purpose: To determine the performance of TOTAL30 for Astigmatism (T30fA; Alcon; Fort Worth, TX, USA) contact lenses (CLs) in existing CL wearers who are also frequent digital device users.

Methods: This 1-month, 3-visit study recruited adult, 18- to 40-year-old subjects who were required to use daily digital devices for at least 8 hours per day. All subjects were refit into T30fA CLs.

View Article and Find Full Text PDF

Objective: The purpose of this study was to investigate the timing and mode of failure of metallic screw-type suture anchors used to attach artificial tendons to bone in an New Zealand White rabbit model.

Study Design: Metal suture anchors with braided composite sutures of varying sizes (United States Pharmacopeia (USP) size 1, 2, or 5) were used to secure artificial tendons replacing both the Achilles and tibialis cranialis tendons in 12 female New Zealand White rabbits. Artificial tendons were implanted either at the time of (immediate replacement,  = 8), or four/five weeks after (delayed replacement,  = 4) resection of the biological tendon.

View Article and Find Full Text PDF

Objective: Minimally invasive dentistry is being widely practiced. The center stone is to be as conservative as possible to minimize unnecessary removal of healthy tooth structure. In prosthodontics the patients have generalized and combined nature of diseases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!