High low-density lipoprotein-cholesterol to high-density lipoprotein-cholesterol (L/H) ratio is associated with progressions of coronary arteriosclerosis and chronic kidney disease. On the other hand, renal function markedly declined after acute myocardial infarction (AMI). The aims of the present study were (1) to identify what type of patients with AMI would have high L/H ratio at follow-up and (2) to evaluate whether decline in renal function after AMI had accelerated or not in patients with high L/H ratio. The 190 eligible AMI patients who underwent primary percutaneous coronary intervention (PCI) and received atorvastatin (10 mg) were divided into one of two groups according to the L/H ratio at 6-month follow-up: L/H >2 group (n = 81) or L/H ≤2 group (n = 109). The characteristics on admission in the two groups were examined. Furthermore, changes in serum creatinine (sCr) and estimated glomerular filtration rate (eGFR) during 1- and 6-month follow-up were compared between the two groups. L/H >2 group were significantly younger and had greater body mass index (BMI) and worse lipid profile on admission compared with L/H ≤2 group. Percentage increase in sCr and percentage decrease in eGFR during 1-month follow-up in L/H >2 group tended to be greater than in L/H ≤2 group, and those during 6-month follow-up were significantly greater (16.5 ± 2.77 vs. 9.79 ± 2.23 %, p = 0.03 and 11.8 ± 1.93 vs. 2.75 ± 3.85 %, p = 0.04, respectively). In AMI patients undergoing primary PCI, those who were young and had large BMI and poor lipid profile on admission were likely to have a high L/H ratio at follow-up despite statin therapy. In addition, the decline in renal function after AMI had significantly accelerated in patients with high L/H ratio.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-012-0321-yDOI Listing

Publication Analysis

Top Keywords

l/h ratio
24
renal function
16
high l/h
16
decline renal
12
patients high
12
l/h
12
6-month follow-up
12
l/h group
12
l/h ≤2
12
≤2 group
12

Similar Publications

Direct Hot Solid-Liquid Extraction (DH-SLE): A High-Yield Greener Technique for Lipid Recovery from Coffee Beans.

Plants (Basel)

January 2025

Departamento de Química, Universidade Federal de Viçosa, Campus Universitário, Avenida Peter Henry Rolfs, s/n, Viçosa 36570-900, MG, Brazil.

Soxhlet extraction is a method recommended by the Association of Official Analytical Chemists (AOAC) to determine the lipid content in plant samples. Generally, n-hexane (toxicity grade 5) is used as the solvent (≈300 mL; ≈30 g sample) at boiling temperatures (69 °C) for long times (≤16 h) under a chilled water reflux (≈90 L/h), proportionally aggravated by the number of repetitions and samples determined. In this sense, the technique is neither safe nor sustainable for the analyst or the environment.

View Article and Find Full Text PDF

Objective: To investigate the prognostic value of baseline European Association of Nuclear Medicine Research Ltd. (EARL) standardized [F]fluorodeoxyglucose positron emission tomography-computed tomography ([F]FDG PET-CT) quantitative values for survival and to evaluate cutoff values identified in other studies.

Materials And Methods: Pediatric and adolescent patients with high-grade osteosarcoma were included.

View Article and Find Full Text PDF

Use of corn carbon as an additive to enhance magnesium metal self-corrosion and recover phosphorus from swine wastewater in the form of struvite.

Environ Res

January 2025

School of Chemistry and Environmental Engineering, Hubei Minzu University, 39 College Road, Enshi, 445000, China. Electronic address:

Recovery of phosphate from swine wastewater is significant for alleviating eutrophication in aquatic ecosystems and addressing the increasing scarcity of phosphorus resources. In this study, a method for phosphate recovery from swine wastewater using corn carbon as an additive and non-dynamic magnesium metal self-corrosion was studied. The effects of reaction time, C:Mg mass ratio, stirring rate, and aeration rate on phosphate recovery were discussed, and eight experimental models were explored.

View Article and Find Full Text PDF

Introduction: The purpose of our study was to evaluate the safety, tolerability, and pharmacokinetics of furaprevir, a new highly selective hepatitis C virus NS3/4A protease inhibitor.

Methods: The study was divided into 2 parts: Part A (single ascending-dose study, SAD) and Part B (multiple ascending-dose study, MAD). A total of 62 healthy subjects were enrolled in the studies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!