Expanded polytetrafluoroethylene (ePTFE) porous material (GORE(®) PRECLUDE(®) Dura Substitute) does not degenerate or deteriorate in vivo, and is currently used as artificial dura mater. This material does not adhere well to the surrounding tissues, but cerebrospinal fluid leakage along the suture line has been observed in several cases. We describe a case of craniotomy for tumor resection performed 14 years after dural repair with ePTFE sheet. Histological examination of the ePTFE sheet revealed that the sheet was structurally intact, with no evidence of tissue adhesion or cellular infiltration. However, collagen deposition was observed around the suture thread. When the suture thread was removed the collagen was also removed, and the original needle hole appeared again. No significant changes were observed in the features of the ePTFE sheet even 14 years postoperatively. The formation of fibrous tissue around the needle hole was important in preventing cerebrospinal fluid leakage.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2176/nmc.53.43 | DOI Listing |
Surg Case Rep
October 2024
Department of Neonatology, Yamanashi Prefectural Central Hospital, Kofu, Japan.
Aesthetic Plast Surg
June 2024
Department of Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan.
Background: Alloplastic chin augmentation is the most common esthetic surgical treatment to reshape the chin. However, factory-made chin implants are typically standardized rather than custom-made and have potential to cause complications. Although the fabrication of custom-made implants by using computer-assisted planning and 3D-printing technology has become widespread, the process has several disadvantages, including long preoperative prosthesis preparation times, high costs, and unsuitability for patients with asymmetric chins or those who undergo combined mandibuloplasty before implant placement.
View Article and Find Full Text PDFInt J Surg Case Rep
November 2023
Cardiovascular Surgery, Nippon Medical School Chiba Hokusoh Hospital, 1715 Kamagari, Inzai-city, Chiba 270-1694, Japan.
Introduction And Importance: The incidence of acquired Gerbode defect has been increasing due to advances in cardiac imaging technology, and some closure methods have been introduced.
Presentation Of Case: A 58-year-old man developed cardiogenic shock due to acute severe aortic valve regurgitation with an acquired Gerbode defect caused by infective endocarditis. Emergency surgery was performed.
Radiat Oncol
October 2023
Department of Surgery, Division of Hepato-Biliary-Pancreatic Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Hyogo, Japan.
Background: Spacer placement surgery is useful in particle therapy (PT) for patients with abdominopelvic malignant tumors located adjacent to the gastrointestinal tract. This study aimed to assess the safety, efficacy, and long-term outcomes of spacer placement surgery using an expanded polytetrafluoroethylene (ePTFE) spacer.
Methods: This study included 131 patients who underwent ePTFE spacer placement surgery and subsequent PT between September 2006 and June 2019.
J Cardiol Cases
July 2023
Department of Cardiology, Showa General Hospital, Tokyo, Japan.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!