Expanded polytetrafluoroethylene (ePTFE) porous material (GORE(®) PRECLUDE(®) Dura Substitute) does not degenerate or deteriorate in vivo, and is currently used as artificial dura mater. This material does not adhere well to the surrounding tissues, but cerebrospinal fluid leakage along the suture line has been observed in several cases. We describe a case of craniotomy for tumor resection performed 14 years after dural repair with ePTFE sheet. Histological examination of the ePTFE sheet revealed that the sheet was structurally intact, with no evidence of tissue adhesion or cellular infiltration. However, collagen deposition was observed around the suture thread. When the suture thread was removed the collagen was also removed, and the original needle hole appeared again. No significant changes were observed in the features of the ePTFE sheet even 14 years postoperatively. The formation of fibrous tissue around the needle hole was important in preventing cerebrospinal fluid leakage.

Download full-text PDF

Source
http://dx.doi.org/10.2176/nmc.53.43DOI Listing

Publication Analysis

Top Keywords

eptfe sheet
12
histological examination
8
expanded polytetrafluoroethylene
8
artificial dura
8
dura mater
8
cerebrospinal fluid
8
fluid leakage
8
suture thread
8
needle hole
8
examination expanded
4

Similar Publications

Article Synopsis
  • Gastroschisis is a birth condition where a baby’s organs stick out through a hole in their belly, and it can be really tough to treat, especially for tiny babies born early.
  • A baby girl, born at just 29 weeks and weighing less than a kilogram, needed special surgery right after birth to help her belly hold her organs better.
  • Although she faced serious health issues like infections and not gaining weight, she eventually got better and was able to go home after 142 days in the hospital.
View Article and Find Full Text PDF

Background: Alloplastic chin augmentation is the most common esthetic surgical treatment to reshape the chin. However, factory-made chin implants are typically standardized rather than custom-made and have potential to cause complications. Although the fabrication of custom-made implants by using computer-assisted planning and 3D-printing technology has become widespread, the process has several disadvantages, including long preoperative prosthesis preparation times, high costs, and unsuitability for patients with asymmetric chins or those who undergo combined mandibuloplasty before implant placement.

View Article and Find Full Text PDF

Introduction And Importance: The incidence of acquired Gerbode defect has been increasing due to advances in cardiac imaging technology, and some closure methods have been introduced.

Presentation Of Case: A 58-year-old man developed cardiogenic shock due to acute severe aortic valve regurgitation with an acquired Gerbode defect caused by infective endocarditis. Emergency surgery was performed.

View Article and Find Full Text PDF

Clinical impact of spacer placement surgery with expanded polytetrafluoroethylene sheet for particle therapy.

Radiat Oncol

October 2023

Department of Surgery, Division of Hepato-Biliary-Pancreatic Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Hyogo, Japan.

Background: Spacer placement surgery is useful in particle therapy (PT) for patients with abdominopelvic malignant tumors located adjacent to the gastrointestinal tract. This study aimed to assess the safety, efficacy, and long-term outcomes of spacer placement surgery using an expanded polytetrafluoroethylene (ePTFE) spacer.

Methods: This study included 131 patients who underwent ePTFE spacer placement surgery and subsequent PT between September 2006 and June 2019.

View Article and Find Full Text PDF
Article Synopsis
  • Contact dermatitis can be a serious issue for patients with metal allergies who undergo cardiac-device implantation, such as ICDs.
  • Wrapping the metal parts of the ICD with expanded polytetrafluoroethylene (ePTFE) sheets has shown promise in preventing this skin condition, with a successful case reported.
  • The inserted ICD initially displayed high shock impedance, which decreased significantly over two weeks, and the patient experienced no skin problems during a 20-month follow-up, though infection risks must still be considered.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!