AI Article Synopsis

  • Arthroscopic rotator cuff repair has gained popularity due to its minimally invasive nature and reduced risk of complications compared to older techniques.
  • The study compared two surgical methods: single-row (SR) and double-row (DR) repair, with results showing a significantly lower re-tear rate in the DR group despite similar clinical outcomes measured by the Constant-Murley Scale and Simple Shoulder Test.
  • The use of 3 Tesla MR imaging, especially with contrast, provided better diagnostic performance for evaluating the success of these surgical techniques.

Article Abstract

Background: Arthroscopic rotator cuff repair has become popular in the last few years because it avoids large skin incisions and deltoid detachment and dysfunction. Earlier arthroscopic single-row (SR) repair methods achieved only partial restoration of the original footprint of the tendons of the rotator cuff, while double-row (DR) repair methods presented many biomechanical advantages and higher rates of tendon-to-bone healing. However, DR repair failed to demonstrate better clinical results than SR repair in clinical trials. MR imaging at 3 Tesla, especially with intra-articular contrast medium (MRA), showed a better diagnostic performance than 1.5 Tesla in the musculoskeletal setting. The objective of this study was to retrospectively evaluate the clinical and 3 Tesla MRA results in two groups of patients operated on for a medium-sized full-thickness rotator cuff tear with two different techniques.

Methods: The first group consisted of 20 patients operated on with the SR technique; the second group consisted of 20 patients operated on with the DR technique. All patients were evaluated at a minimum of 3 years after surgery. The primary end point was the re-tear rate at 3 Tesla MRA. The secondary end points were the Constant-Murley Scale (CMS), the Simple Shoulder Test (SST) scores, surgical time and implant expense.

Results: The mean follow-up was 40 months in the SR group and 38.9 months in the DR group. The mean postoperative CMS was 70 in the SR group and 68 in the DR group. The mean SST score was 9.4 in the SR group and 10.1 in the DR group. The re-tear rate was 60% in the SR group and 25% in the DR group. Leakage of the contrast medium was observed in all patients.

Conclusions: To the best of our knowledge, this is the first report on 3 Tesla MRA in the evaluation of two different techniques of rotator cuff repair. DR repair resulted in a statistically significant lower re-tear rate, with longer surgical time and higher implant expense, despite no difference in clinical outcomes. We think that leakage of the contrast medium is due to an incomplete tendon-to-bone sealing, which is not a re-tear. This phenomenon could have important medicolegal implications. Level of evidence III. Treatment study: Case-control study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3576341PMC
http://dx.doi.org/10.1186/1471-2474-14-43DOI Listing

Publication Analysis

Top Keywords

rotator cuff
20
cuff repair
12
contrast medium
12
tesla mra
12
patients operated
12
re-tear rate
12
group
10
arthroscopic rotator
8
repair
8
repair clinical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!