Report of methamphetamine use and cardiomyopathy in three patients.

Daru

Clinical Toxicology Department, Loghman Hakim Hospital Poison Center, Faculty of Medicine, and Toxicological Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

Published: August 2012

Background: Methamphetamine (meth) is a stimulant used illegally around the world, including in Iran. Cardiomyopathy and cardiac failure may occur following chronic meth use and may cause the patients referred to the emergency department.

Case Reports: A 28-year old man and two women, ages 29 and 31-year-old, with a history of meth use, were admitted to the emergency department with severe dyspnea at rest. Each had sinus tachycardia with tachypnea and an echocardiogram that showed severe systolic dysfunction consistent with heart failure. Additional evaluation in the hospital revealed cardiomyopathy with no other etiology other than the meth use.

Conclusion: There are several reports that show an increase in frequency of meth use, suggesting that cardiomyopathy and acute heart failure may be a new medical concern.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3555706PMC
http://dx.doi.org/10.1186/2008-2231-20-20DOI Listing

Publication Analysis

Top Keywords

heart failure
8
meth
5
report methamphetamine
4
cardiomyopathy
4
methamphetamine cardiomyopathy
4
cardiomyopathy three
4
three patients
4
patients background
4
background methamphetamine
4
methamphetamine meth
4

Similar Publications

Type 2 diabetes (T2D) frequently coexists with cardiorenal complications. Therefore, a holistic approach to patient management is required, with specialists such as primary care physicians, cardiologists, endocrinologists, and nephrologists working together to provide patient care. Although glycemic control is important in the management of T2D, patients with T2D and acceptable glycemic control are still at risk from cardiovascular (CV) events such as stroke, heart attack, and heart failure (HF).

View Article and Find Full Text PDF

Background: Interventricular dyssynchrony derived from the classic non-physiological stimulation (n-PS) of the right ventricle (RV) is a known cause of left ventricular dysfunction (LVDys).

Methods: This was a prospective descriptive single-center study. We analyzed patients who develop LVDys with n-PS, and the results after upgrading to conduction system pacing (CSP).

View Article and Find Full Text PDF

Left atrial strain (LAS) was recently introduced as a parameter that reflects on left atrial function. Consequently, changes in LAS can inform the development of cardiovascular diseases, hence providing a window for non-invasive and cost-effective testing of these diseases and their complications at early stages of development, potentially offering a segway towards preventive interventions. LAS has yet to be implemented into standard practice.

View Article and Find Full Text PDF

Background: Little is known about how younger and older hospitalized patients differ with respect to reasons for admission, comorbidities, diagnostics, treatment and intercurrent problems.

Objective: The aim of the study was to compare the previously named characteristics in the clinical profile of patients > 90 years old (nonagenarians) with a control group of patients 70-75 years old admitted to an emergency hospital department for internal medicine and cardiology.

Material And Method: The study included all consecutive nonagenarians and gender-matched control patients who were admitted during 2011.

View Article and Find Full Text PDF

Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.

Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.

Results: The majority of patients (87.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!