Background: Heparin-induced thrombocytopenia (HIT) is caused by platelet-activating antibodies that recognize platelet factor 4/heparin (PF4/hep) complexes. The in vitro demonstration of PF4/hep antibodies using functional and immunological methods is essential for optimal management of patients suspected to have HIT. Since functional assays are technically challenging and limited to specialized laboratories, antigen-binding assays are commonly used in routine laboratories.
Study Design: Blood samples from 448 consecutive patients in whom HIT was suspected were investigated using a latex agglutination test HemosIL® HIT-Ab(PF4-H) (HemosIL-Ab), two chemiluminescence tests HemosIL AcuStar HIT-Ab(PF4-H) (HemosIL AcuStar-Ab) and AcuStar HIT-IgG(PF4-H) (HemosIL AcuStar-IgG), an in-house PF4/hep IgG enzyme immunoassay (EIA) and the heparin induced platelet aggregation (HIPA) test.
Results: Antibodies against PF4/hep were detectable in 44 out of 119 samples using HemosIL-Ab among which 20 samples were also reactive in the HIPA; and in 122, 64 and 108 out of 448 sera using HemosIL AcuStar-Ab, HemosIL AcuStar-IgG and in-house PF4/hep IgG-EIA, respectively, among which 52 sera were also reactive in the HIPA. All assays had high sensitivities of >95% for platelet activating antibodies; however, they differed in their specificities. The highest specificity and positive predictive value was observed by HemosIL AcuStar-IgG (96% and 78%, respectively).
Conclusion: Automated immunoassays are useful in the laboratory investigations of HIT and present a potential improvement toward standardization of laboratory investigations of HIT. The high positive predictive capability may justify treating the patient with alternative anticoagulants without waiting for the results of a functional assay.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.thromres.2013.01.005 | DOI Listing |
J Thromb Thrombolysis
August 2021
Laboratoire d'Hématologie, La Timone Hospital, APHM, Boulevard Jean- Moulin, 13005, Marseille, France.
Heparin induced thrombocytopenia (HIT) is a life and limb-threatening complication of heparin exposure. The misdiagnosis of this disease can have major consequences on the patients. The objective of this study was to evaluate a diagnostic strategy that combines the 4Ts score with the result of HemosIL® AcuStar HIT-IgG (PF4-H) to confirm the diagnosis of HIT.
View Article and Find Full Text PDFThromb Res
March 2013
Institute for Immunology and Transfusion Medicine, Ernst-Moritz-Arndt University Greifswald, Germany.
Background: Heparin-induced thrombocytopenia (HIT) is caused by platelet-activating antibodies that recognize platelet factor 4/heparin (PF4/hep) complexes. The in vitro demonstration of PF4/hep antibodies using functional and immunological methods is essential for optimal management of patients suspected to have HIT. Since functional assays are technically challenging and limited to specialized laboratories, antigen-binding assays are commonly used in routine laboratories.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!