We report three patients who had intravascular catheter fragments removed using an easily made snare device fashioned from a 0.038 inch movable-core J-wire and a multi-purpose catheter. The device is easily manipulated and facilitates safe removal of embolized catheters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.1810190407 | DOI Listing |
Retina
February 2025
Department of Ophthalmology, Liyang Hospital of Chinese Medicine, Liyang, China.
Purpose: To describe a custom bent 27-gauge needle-guided suture snare technique for scleral fixation of posterior chamber intraocular lenses (PCIOL).
Methods: An 8-0 polypropylene suture was threaded into the lumen of a custom bent 27-gauge needle, and the needle tip was advanced into the eye from the intraocular lens (IOL) fixation point. The suture was threaded through the posterior limbal incision inside the IOL haptic loop and pulled out.
Catheter Cardiovasc Interv
January 2025
Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Mexico City, Mexico.
The use of the snare catheter (SC) technique has been described in the field of interventional cardiology, in particular in the retrieval of a lost device, for example, a dislodged coronary stent, broken coronary wire, and so forth. In the transcatheter aortic valve replacement (TAVR) procedure, some cases have been observed where the anatomy is challenging or there are scenarios where some complications occur during the procedure, which make it necessary to use some tools to achieve the success of the procedure. The SC has shown are very useful either to achieve the ascent of the valve to the annular plane in complex anatomies or as a rescue measure in the event of complications that may arise after valve implantation.
View Article and Find Full Text PDFJ Innov Card Rhythm Manag
December 2024
Department of Electrophysiology, MedStar Health: Heart and Vascular Institute at MedStar Washington Hospital Center, Washington, DC, USA.
Leadless pacemakers (LPs) are emerging options for bradyarrhythmias. However, extraction can be risky if the device is in an unfavorable position. We present a challenging case of a Nanostim LP (NLP) (Abbott Medical Inc.
View Article and Find Full Text PDFAccurate size measurement of colorectal polyps is critical for clinical decision making and patient management. This systematic review aimed to evaluate the current techniques used for colonic polyp measurement to improve the reliability of size estimations in routine practice.A comprehensive literature search was conducted across PubMed, EMBASE, and MEDLINE to identify studies relevant to size measurement techniques published between 1980 and March 2024.
View Article and Find Full Text PDFRev Esp Enferm Dig
January 2025
Gastroenterology, Yokkaichi Municipal Hospital.
Purpose: High-frequency surgical devices with various functionalities are widely used in Europe and Japan. In this study, we evaluated the effectiveness of the maXium HF surgical device manufactured by KLS Martin (Germany) during endoscopic mucosal resection (EMR).
Materials And Methods: The maXium device offers multiple preconfigured modes for incision and coagulation tailored to different surgical procedures.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!