A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Isometric handgrip exercise during cardiovascular magnetic resonance imaging: set-up and cardiovascular effects. | LitMetric

Purpose: To establish a suitable setup for combining isometric handgrip exercise with cardiovascular magnetic resonance (CMR) imaging and to assess cardiovascular effects.

Materials And Methods: Fifty-three healthy volunteers (31 males, mean age 45 ± 17 years) underwent handgrip exercise in a 3T scanner using a prototype handgrip system and a custom-made feedback system that displayed the force. Handgrip was sustained at 30% of the maximal contraction for 6-8 minutes. Heart rate, blood pressure (BP), and double product were determined sequentially. Stroke volume was quantified in a subgroup (n = 21) at rest and stress using phase contrast acquisitions.

Results: Heart rate increased significantly between rest and stress by 20 ± 13%, systolic / diastolic / mean BP by 15 ± 11% / 20 ± 18% / 17 ± 13%, double product by 37 ± 21%, and cardiac output by 27 ± 16% (each P < 0.001). Stroke volume did not significantly increase (3 ± 9%; P = 0.215). Higher age was associated with reduced increase of stroke volume (P = 0.022) and cardiac output (P < 0.001). Overweight subjects showed less increases in heart rate (P = 0.021) and cardiac output (P = 0.002).

Conclusion: The handgrip exercise during CMR with the presented set-up leads to considerable hemodynamic changes in healthy volunteers.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.23924DOI Listing

Publication Analysis

Top Keywords

handgrip exercise
16
heart rate
12
stroke volume
12
cardiac output
12
isometric handgrip
8
exercise cardiovascular
8
cardiovascular magnetic
8
magnetic resonance
8
healthy volunteers
8
double product
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!