Purpose: The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapted to High Dose Rate (HDR). This work sets nomograms for LDR and HDR prostate-BT implants, which are applied to three different institutions that use different implant techniques.
Material And Methods: Patients treated throughout 2010 till April 2011 were considered for this study. This example was chosen to be the representative of the latest implant techniques and to ensure consistency in the planning. A sufficient number of cases for both BT modalities, prescription dose and different work methodology (depending on the institution) were taken into account. The specific nomograms were built using the correlation between the prostate volume and some characteristic parameters of each BT modality, such as the source Air Kerma Strength, number of implanted seeds in LDR or total radiation time in HDR.
Results: For each institution and BT modality, nomograms normalized to the prescribed dose were obtained and fitted to a linear function. The parameters of the adjustment show a good agreement between data and the fitting. It should be noted that for each institution these linear function parameters are different, indicating that each centre should construct its own nomograms.
Conclusions: Nomograms for LDR and HDR prostate brachytherapy are simple quality assurance tools, specific for each institution. Nevertheless, their use should be complementary to the necessary independent verification.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3551356 | PMC |
http://dx.doi.org/10.5114/jcb.2011.24817 | DOI Listing |
Ann Transplant
December 2024
Department of Urology, Nara Medical University, Kashihara, Nara, Japan.
BACKGROUND Despite its surgical complexity, kidney transplantation (KT) with multiple renal arteries (MRA) is comparable in performance to KT with a single renal artery (SRA). This study aimed to evaluate the effect of MRA and to investigate risk factors for graft loss in living-donor KT with MRA. MATERIAL AND METHODS This study included living-donor KT recipients who underwent KT in our hospital from February 2002 to March 2023.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
January 2025
McGill university, Montreal, Qc, Canada.
Purpose: High dose rate (HDR) prostate brachytherapy (BT) procedure requires image-guided needle insertion. Given that general anesthesia is often employed during the procedure, minimizing overall planning time is crucial. In this study, we explore the clinical feasibility and time-saving potential of artificial intelligence (AI)-driven auto-reconstruction of transperineal needles in the context of US-guided prostate BT planning.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Radiobiology and Diagnostic Onco-Cytogenetics, Centre of Radiotherapy, National Institute of Oncology, 1122, Ráth György utca 7-9, Budapest, Hungary.
Due to the better survival of patients with tumorous diseases, it is increasingly important to predict the side effects of radiotherapy, for which the Radiation-Induced Lymphocyte Apoptosis (RILA) method is proving to be effective in multicentric studies. Prostate cancer is the leading cause of cancer-related deaths among men worldwide, which is usually treated with radiotherapy. We recruited 49 patients with localized prostate cancer and performed RILA measurements before radiotherapy.
View Article and Find Full Text PDFRep Pract Oncol Radiother
December 2024
Brachytherapy Department, Greater Poland Cancer Centre, Poznan, Poland.
Rep Pract Oncol Radiother
December 2024
Department of Biomedical Physics, Faculty of Physics, Adam Mickiewicz University, Poznań, Poland.
Background: The purpose of this study is to determine the effect of the type of I-125 radioactive source on dose distribution in the planning process of ultra-low dose rate (uLDR) prostate brachytherapy.
Material And Methods: 7 patients who had undergone brachytherapy in our center were included in the study. Dose in five geometrical points were analyzed for 12 types of implants that are available on the market.