AI Article Synopsis

Article Abstract

Image-guided microsurgery requires accuracies an order of magnitude higher than today's navigation systems provide. A critical step toward the achievement of such low-error requirements is a highly accurate and verified patient-to-image registration. With the aim of reducing target registration error to a level that would facilitate the use of image-guided robotic microsurgery on the rigid anatomy of the head, we have developed a semiautomatic fiducial detection technique. Automatic force-controlled localization of fiducials on the patient is achieved through the implementation of a robotic-controlled tactile search within the head of a standard surgical screw. Precise detection of the corresponding fiducials in the image data is realized using an automated model-based matching algorithm on high-resolution, isometric cone beam CT images. Verification of the registration technique on phantoms demonstrated that through the elimination of user variability, clinically relevant target registration errors of approximately 0.1 mm could be achieved.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2013.2241063DOI Listing

Publication Analysis

Top Keywords

patient-to-image registration
8
image-guided robotic
8
robotic microsurgery
8
target registration
8
registration
5
high-accuracy patient-to-image
4
registration facilitation
4
facilitation image-guided
4
microsurgery head
4
head image-guided
4

Similar Publications

Article Synopsis
  • Robotics in neurosurgery is increasingly used, particularly with the incorporation of intraoperative imaging for precise patient registration in a new lightweight, table-mounted robotic system designed for cranial biopsies and sEEG procedures.
  • The study evaluated 26 patients using the Cirq system for stereotactic biopsy or sEEG from January 2023 to August 2024, comparing results with data from the frameless VarioGuide system, specifically looking at entry errors, target errors, and vector deviation of electrodes.
  • Results indicated that Cirq-assisted procedures had a mean surgical time of about 117 minutes for biopsies and 269 minutes for sEEG, revealing differences in efficiency compared to VarioGuide, where the comparable
View Article and Find Full Text PDF

Stereotactic Navigation-Assisted Laparoscopic Resection of Challenging Low Pelvic Tumors: A Case Series.

J Clin Med

February 2024

Division of Colon and Rectal Surgery, Department of Surgery, Korea University Anam Hospital, Korea University College of Medicine, Goryeodae-ro, Seongbuk-gu 73, Seoul 02841, Republic of Korea.

(1) : The laparoscopic approach to low pelvic tumors is challenging and hindered by suboptimal tumor visualization and dissection, with possible oncological failure. Stereotactic navigation provides real-time image guidance that may optimize safety, accuracy, and precision when dissecting challenging low pelvic tumors. (2) Preoperative CT images were acquired with eight skin-fixed fiducials and loaded into a navigation system.

View Article and Find Full Text PDF
Article Synopsis
  • We introduced a new technique for aligning intraoperative images with patient-specific views using preoperative imaging and expected appearances.
  • Our method improves camera pose estimation by comparing intraoperative images with synthesized expected views, effectively addressing issues related to low-quality images during surgery.
  • Testing on both synthetic and clinical data showed that our approach surpassed existing methods, achieving accuracies that fulfill clinical requirements in brain surgery.
View Article and Find Full Text PDF

Purpose: Patient-to-image registration is a preliminary step required in surgical navigation based on preoperative images. Human intervention and fiducial markers hamper this task as they are time-consuming and introduce potential errors. We aimed to develop a fully automatic 2D registration system for augmented reality in ear surgery.

View Article and Find Full Text PDF
Article Synopsis
  • The Cirq robotic alignment system is a manually adjustable electronic arm designed to help neurosurgeons accurately align instruments for brain tumor biopsies.
  • A study was conducted with 37 pediatric patients, comparing outcomes from the Cirq system and a non-robotic system, Varioguide, assessing registration accuracy and biopsy errors.
  • Results showed that while Cirq had a slightly lower target error, both systems were similarly effective and safe for performing intracranial biopsies.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!