A portable capillary electrophoresis instrument featuring an automated, robust, valve-based injection system was developed. This significantly facilitates operation in the field compared to previous injection approaches. These generally required delicate manual operations which are difficult to perform outside the laboratory environment. The novel system relies on pressurized air for solution delivery and a micromembrane pump for sample aspiration. Contactless conductivity detection was employed for its versatility and low power requirement. The instrument has a compact design, with all components arranged in a briefcase with dimensions of 45 × 35 × 15 cm (w × d × h) and a weight of about 8 kg. It can operate continuously for 9 h in the battery-powered mode. Depending on the task at hand, the injection system allows easy optimization for high separation efficiency, for fast separations, or for low limits of detection. To illustrate these features, the separation of four anions within 16 s is demonstrated as well as the determination of nitrite below 1 μM. The determination of phosphate at a sewage treatment plant was carried out to demonstrate a field application.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac303328gDOI Listing

Publication Analysis

Top Keywords

portable capillary
8
capillary electrophoresis
8
electrophoresis instrument
8
contactless conductivity
8
conductivity detection
8
injection system
8
instrument automated
4
automated injector
4
injector contactless
4
detection portable
4

Similar Publications

A Droplet Microfluidic Sensor for Point-of-Care Measurement of Plasma/Serum Total Free Thiol Concentrations.

Anal Chem

January 2025

Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, U.K.

Total free thiols are an important marker of the whole-body redox state, which has been shown to be associated with clinical outcome in health and disease. Recent investigations have suggested that increased insight may be gained by monitoring alterations of redox state in response to exercise and hypoxia and to monitor redox trajectories in disease settings. However, conducting such studies is challenging due to the requirement for repeated venous blood sampling and intensive lab work.

View Article and Find Full Text PDF

A Reusable Capillary Flow-Driven Microfluidic System for Abscisic Acid Detection Using a Competitive Immunoassay.

Sensors (Basel)

January 2025

Instituto de Engenharia de Sistemas e Computadores-Microsistemas e Nanotecnologias (INESC-MN), Rua Alves Redol, 1000-029 Lisbon, Portugal.

Point-of-care (PoC) devices offer a promising solution for fast, portable, and easy-to-use diagnostics. These characteristics are particularly relevant in agrifood fields like viticulture where the early detection of plant stresses is crucial to crop yield. Microfluidics, with its low reagent volume requirements, is well-suited for such applications.

View Article and Find Full Text PDF

Introduction: Hemoglobin (Hb) estimation in blood donors is conducted using capillary samples on portable hemoglobinometers, representing measurement methods in practice. The reference standard is conducted using a venous sample on a hematology analyzer, representing the mentor measurement method or the true value. The correction involves the calculation of the secondary adjustment factor (SAF) to mitigate the difference between the two values.

View Article and Find Full Text PDF

Advances in the design and application of contactless conductivity detectors for separation, flow-through, microfluidic and sensing techniques: A review.

Anal Chim Acta

February 2025

Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague 10, Czech Republic. Electronic address:

The review focuses on the design of detection cells, the use of microcontrollers for processing and evaluation of the detection signal, and the development of multi-detection systems for electromigration, liquid chromatography, flow-through and microfluidic techniques. A separate section is the introduction of modern 3D printing techniques and the use of new printing materials for the design of multidetection systems. In addition to traditional utilisation in separation techniques, new versions of contactless conductivity detectors are finding applications in FIA, SIA, portable and paper based analytical systems or as independent sensors.

View Article and Find Full Text PDF

Evaluation of the Performance of Portable Hemoglobinometers at Measuring Hemoglobin and Detecting Anemia in a Periurban Pediatric Population in Lima, Peru.

Am J Trop Med Hyg

December 2024

Laboratorio de Bioinformática, Biología Molecular y Desarrollos Tecnológicos, Laboratorios de Investigación y Desarrollo, Facultad de Ciencias e ingeniería, Universidad Peruana Cayetano Heredia.

As many as one in three people worldwide have anemia, with young children at increased risk of both disease and complications. In settings without clinical laboratories, portable hemoglobinometers serve important roles in diagnosing anemia and estimating prevalence. Here, we assess the validity of two such point-of-care devices-the HemoCue Hb201 and the HemoCue Hb301-relative to the international reference standard, the cyanmethemoglobin method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!