Nanomaterials play a significant role in biomedical research and applications because of their unique biological, mechanical, and electrical properties. In recent years, they have been utilized to improve the functionality and reliability of a wide range of implantable medical devices ranging from well-established orthopedic residual hardware devices (e.g., hip implants) that can repair defects in skeletal systems to emerging tissue engineering scaffolds that can repair or replace organ functions. This review summarizes the applications and efficacies of these nanomaterials that include synthetic or naturally occurring metals, polymers, ceramics, and composites in orthopedic implants, the largest market segment of implantable medical devices. The importance of synergistic engineering techniques that can augment or enhance the performance of nanomaterial applications in orthopedic implants is also discussed, the focus being on a low-intensity direct electric current (LIDC) stimulation technology to promote the long-term antibacterial efficacy of oligodynamic metal-based surfaces by ionization, while potentially accelerating tissue growth and osseointegration. While many nanomaterials have clearly demonstrated their ability to provide more effective implantable medical surfaces, further decisive investigations are necessary before they can translate into medically safe and commercially viable clinical applications. The article concludes with a discussion about some of the critical impending issues with the application of nanomaterials-based technologies in implantable medical devices, and potential directions to address these.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3638956 | PMC |
http://dx.doi.org/10.1002/wnan.1201 | DOI Listing |
Sci Rep
December 2024
Department of Vascular Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Intraluminal prosthetic graft thrombus (IPT) has been described in case of endovascular aortic pathology repair. This study aimed to assess hemodynamic indicators associated with various anatomical morphologies following endovascular aortic repair (EVAR), aiming to offer further references for the choice of clinical therapy. Six model models (normal, iliac compression, aortic compression, aortoiliac compression, iliac distortion, and long-leg stent) were established based on common anatomical morphologies following EVAR.
View Article and Find Full Text PDFSci Rep
December 2024
Fertility and IVF Unit, Department of Obstetrics and Gynecology, Soroka University Medical Center, Beer Sheva, 151, Israel.
It has long been speculated that the mechanical properties of the human oocyte can be an indicator for oocyte viability. Recent studies have demonstrated that embryo implantation rates, following Intra-Cytoplasmic Sperm Injection (ICSI) procedures, may be increased if the shear modulus value of the oocyte Zona Pellucida (ZP) is taken into consideration during embryo transfer. The shear modulus was determined by an iterative oocyte specific finite element (FE) analysis based on the clinical ICSI data.
View Article and Find Full Text PDFSci Rep
December 2024
Student Research Committee, Department of Epidemiology, School of Public Health and Safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Very high heat is generated during the polymerization of poly (methyl methacrylate) (PMMA) bone cement, which is used for implant fixation in orthopedic surgery. As such, it has been suggested that irrigating the bone cement layer in the surgical site with a saline solution is a way of cooling the layer. In this study, we aimed to determine the influence of irrigation with a saline solution on the flexural strength and the microstructure of the test specimens of two PMMA bone cement brands: Simplex P and FIX 1.
View Article and Find Full Text PDFSci Rep
December 2024
Center for Surgical Innovation and Engineering, Cedars Sinai Health System, Los Angeles, 90048, USA.
Mechanical failure of medical implants, especially in orthopedic poses a significant burden to the patients and healthcare system. The majority of the implant failures are diagnosed at very late stages and are of mechanical causes. This makes the diagnosis and screening of implant failure very challenging.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Orthopedic Surgery, National Clinical Research Center for Geriatric Disorders, Hunan Engineering Research Center of Biomedical Metal and Ceramic Implants, Xiangya Hospital, Central South University, Changsha, 410008, China.
Osteoarthritis (OA) has been the most common arthritis affecting public health all over the world. Previous experimental research reported that increased low-density lipoprotein cholesterol, along with decreased high-density lipoprotein cholesterol may be associated with increased ectopic bone formation and possible knee OA, while clinical evidence is absent. This study aimed to investigate the association between blood high-density lipoprotein cholesterol (HDL-C) and OA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!