Background: Prostate cancer is the most common malignancy and second leading cause of cancer related deaths in American men supporting the study of prostate cancer chemoprevention. Major risk factors for this disease have been associated with low serum levels of vitamin D. Here, we evaluate the biologic activity of a less calcemic vitamin D analog 1α-hydroxyvitamin D2 [1α-OH-D2] (Bone Care International, Inc.) in patients with prostate cancer and high grade prostatic intraepithelial neoplasia (HG PIN).
Methods: Patients with clinically organ-confined prostate cancer and HG PIN were randomized to 1α-OH-D2 versus placebo for 28 days prior to radical prostatectomy. Intermediate endpoint biomarkers included serum vitamin D metabolites, TGFß 1/2, free/total PSA, IGF-1, IGFBP-3, bFGF, and VEGF. Tissue endpoints included histology, MIB-1 and TUNEL staining, microvessel density and factor VIII staining, androgen receptor and PSA, vitamin D receptor expression and nuclear morphometry.
Results: The 1α-OH-D2 vitamin D analog was well tolerated and could be safely administered with good compliance and no evidence of hypercalcemia over 28 days. While serum vitamin D metabolite levels only slightly increased, evidence of biologic activity was observed with significant reductions in serum PTH levels. TGF-ß2 was the only biomarker significantly altered by vitamin D supplementation. Whether reduced TGF-ß2 levels in our study is an early indicator of response to vitamin D remains unclear.
Conclusions: While further investigation of vitamin D may be warranted based on preclinical studies, results of the present trial do not appear to justify evaluation of 1α-OH-D2 in larger clinical prostate cancer prevention studies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3755376 | PMC |
http://dx.doi.org/10.1002/pros.22644 | DOI Listing |
J Mater Chem B
January 2025
Department of Electrical, Electronics and Communication Engineering, Indian Institute of Technology Dharwad, Karnataka - 580011, India.
Prostate cancer antigen 3 (PCA3) has emerged as a critical biomarker for the early detection of prostate cancer, complementing the traditional prostate-specific antigen (PSA) testing. This research presents a novel resistive sensor based on reduced graphene oxide (RGO) functionalized with glutaraldehyde (GA)/complementary single-stranded DNA (ss-DNA) for the detection of the PCA3 RNA. The device was meticulously characterized at each fabrication step to confirm the successful integration of the various layers on the sensor device, utilizing atomic force microscopy (AFM) which confirmed the increase in the thickness of the sensor from ∼1.
View Article and Find Full Text PDFCA Cancer J Clin
January 2025
Division of Medical Oncology, Department of Internal Medicine, Huntsman Cancer Institute, University of Utah, Salt Lake City, Utah, USA.
Poly(adenosine diphosphate ribose) polymerase (PARP) inhibitors, such as olaparib, talazoparib, rucaparib, and niraparib, comprise a therapeutic class that targets PARP proteins involved in DNA repair. Cancer cells with homologous recombination repair defects, particularly BRCA alterations, display enhanced sensitivity to these agents because of synthetic lethality induced by PARP inhibitors. These agents have significantly improved survival outcomes across various malignancies, initially gaining regulatory approval in ovarian cancer and subsequently in breast, pancreatic, and prostate cancers in different indications.
View Article and Find Full Text PDFProstate cancer (PCa) has high prevalence rates in men and is a leading cause of cancer-related death. Transrectal (TR) biopsy has traditionally been the gold standard for diagnosis, but transperineal (TP) biopsy is increasingly favoured due to its lower infection risk. However, debate remains regarding which method has superior cancer detection rates.
View Article and Find Full Text PDFPurpose: In prostate and breast cancer, moderate hypofractionation (HF) has demonstrated comparable, if not greater, efficacy than conventional fractionation. There is a stark disparity in the uptake of HF between North America and Africa. Using the Consolidative Framework for Implementation Research, we evaluated barriers and facilitators for implementing HF in Sub-Saharan Africa (SSA).
View Article and Find Full Text PDFIndian J Nucl Med
November 2024
Department of Nuclear Medicine and Molecular Imaging, Homi Bhabha Cancer Hospital and Mahamana Pandit Madan Mohan Malaviya Cancer Centre, Tata Memorial Centre, Homi Bhabha National Institute, Varanasi, Uttar Pradesh, India.
Background: Prostate-specific membrane antigen (PSMA) has shown to be a promising agent for prostate cancer imaging under PET-CT. With the automation in radiolabeling with 68Ga, using iTG 68Ge/68Ga generator, it has helped introduce various new diagnostic agents and achieve good manufacturing practices (GMP) simultaneously. However, before any radiopharmaceutical is put into clinical usage, it should always be checked for its radiochemical purity and other quality parameters before injecting in the patient.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!