No routine coagulation laboratory test is recommended during rivaroxaban or dabigatran treatment. However measuring drug concentration and/or anticoagulant activity can be desirable in some special clinical settings, such as bleeding, thrombosis recurrence or emergency surgery. The effects of dabigatran etexilate and rivaroxaban on various coagulation assays have been previously studied in normal plasma spiked with increasing concentrations of the drug. In contrast, few data are available in routinely treated patients. In order to perform and to interpret the results of these tests, it is necessary to determine the usual responses of patient's plasma. We have used several coagulation tests in a prospective study including 106 patients receiving thromboprophylactic treatment with dabigatran 150 or 220 mg od and rivaroxaban 10 mg od for major orthopaedic surgery. The most common tests--prothrombin time (PT) and activated partial thromboplastin time (aPTT)--give results, which vary according to the reagent used. To overcome this limitation, we advocate the use of plasma calibrators, which decreases the inter-laboratory heterogeneity of results. Anti-Xa measurement and Hemoclot, a thrombin diluted clotting assay, are specific assays which have been proposed for rivaroxaban and dabigatran respectively. These tests, conventional PT, aPTT and thrombin generation (TG) have been performed. We demonstrated that measurements of both drugs can determine reliably the drug concentration in patients' plasmas. PT is more prolonged with rivaroxaban than with dabigatran. Interestingly, the pattern of TG was clearly different in relation to the difference in the mechanism of action of the two new anticoagulants. A significant inter-individual variability of response is detected. Rivaroxaban--mean Cmax 140 ng/mL (extremes 0-412) induces a greater increase of PT than dabigatran. aPTT is sensitive to dabigatran. Rivaroxaban concentrations were in good agreement with two other studies while unexplained lower than expected concentrations were found in dabigatran patients receiving 220 mg once a day [mean Cmax 60 ng/mL (extremes 0-320)]. An interference by pantoprazole, a drug which reduces dabigatran absorption, could explain the observed lower than expected results.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11239-012-0803-xDOI Listing

Publication Analysis

Top Keywords

rivaroxaban dabigatran
12
dabigatran
9
dabigatran rivaroxaban
8
106 patients
8
drug concentration
8
patients receiving
8
ng/ml extremes
8
lower expected
8
rivaroxaban
7
measurement dabigatran
4

Similar Publications

The prevalence and factors associated with potentially inappropriate medications in Chinese older outpatients with heart failure.

BMC Geriatr

December 2024

Department of Pharmacy, National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China.

Background: Potentially inappropriate medications (PIMs) can lead to adverse outcomes. This study aimed to investigate the prevalence of PIMs in older Chinese outpatients with heart failure according to the 2019 Beers criteria and the factors associated with PIMs.

Methods: A cross-sectional retrospective study was conducted using electronic medical data during January 1, 2020 to December 31, 2020 from 9 tertiary medical institutions in Chengdu, China.

View Article and Find Full Text PDF

Background: Inferior vena cava agenesis (IVCA) is a rare vascular abnormality characterised by the absence of one or more segments of the inferior vena cava and represents an underestimated cause of deep vein thrombosis (DVT). Given the very low prevalence of this condition and the lack of clinical trials, there is no consensus about the optimal anticoagulation strategy in IVCA-associated DVT.

Objectives: To investigate efficacy and safety of direct oral anticoagulants (DOACs) in IVCA-associated DVT.

View Article and Find Full Text PDF

Although several antithrombotic strategies have been investigated for the management of cryptogenic strokes, ie, ischemic strokes without known etiologies, an optimal antithrombotic strategy for cryptogenic strokes is unknown. We aim to assess oral antithrombotic agents' comparative efficacy and safety after cryptogenic stroke to identify an optimal treatment.A systematic review and meta-analysis synthesizing evidence from randomized controlled trials (RCTs) obtained from PubMed, Embase Cochrane, Scopus, and Web of Science until February 2024.

View Article and Find Full Text PDF

Direct Oral Anticoagulants in Budd-Chiari Syndrome.

Eur J Haematol

December 2024

Department of Medicine, Division of Hematology/Oncology, University of South Florida, Tampa, Florida, USA.

Aims: Budd-Chiari syndrome (BCS) is managed by interventions aimed at relieving hepatic venous obstruction and anticoagulation. Despite robust data supporting the tolerability and efficacy of direct oral anticoagulants (DOACs) in patients with other venous thromboembolism, its utility in BCS is not well documented. This study aims to evaluate the efficacy and tolerability of DOACs in Primary BCS from the available literature.

View Article and Find Full Text PDF

Development and validation of a quantification method for direct oral anticoagulants from capillary blood using volumetric absorptive microsampling and online SPE-LC-MS.

J Chromatogr B Analyt Technol Biomed Life Sci

December 2024

Department of Pharmaceutical and Medical Chemistry, Clinical Pharmacy, University of Muenster, Muenster, Germany. Electronic address:

The number of prescriptions for new direct oral anticoagulants (DOACs) apixaban, edoxaban, rivaroxaban and dabigatran has increased exponentially in recent years, increasingly replacing the old gold standard, vitamin-K-antagonists. Due to their wide therapeutic range, therapeutic drug monitoring (TDM) is not required, although it has been proven that this could significantly reduce side effects. In order to develop a cost-efficient and simple method for the simultaneous detection of the DOACs and phenprocoumon, a new technology for sample preparation from capillary blood in the ambulant sector named VAMS® was integrated and an LC-MS detector with on-line solid phase extraction (SPE) applying a Turboflow HTLC Cyclone 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!