Background Context: Although the Cobb method is considered the gold standard, the centroid method may offer a reasonable alternative in adult scoliosis because it has better inter- and intraobserver reliabilities in adolescent scoliosis.
Purpose: To compare the reliabilities of the Cobb and the centroid methods for measuring coronal curvature in degenerative scoliosis in older patients.
Study Design: Observational study involving three examiners.
Patient Sample: Sixty whole spine posteroanterior (PA) radiographs were collected.
Outcome Measures: Data were analyzed to determine inter- and intraobserver reliabilities.
Methods: Sixty whole spine PA radiographs of patients older than 60 years were collected to compare the reliabilities of the centroid and the Cobb methods for measuring coronal curvature in degenerative scoliosis. Three examiners using both methods independently measured radiographs twice. Data were analyzed to determine inter- and intraobserver reliabilities.
Results: Intraobserver comparisons of all the 60 radiographs revealed that inter- and intraclass correlation coefficients (ICCs) of the Cobb and the centroid methods were both excellent (greater than 0.979 vs. greater than 0.918), and mean absolute differences (MADs) were similar (less than 1.58 vs. less than 2.02). In interobserver comparisons, ICCs of the Cobb method were higher than that of the centroid method (greater than 0.922 vs. greater than 0.799), and the MADs of the Cobb method were lower than that of the centroid method (less than 2.91 vs. less than 4.84). Comparisons of radiographs subdivided by severity showed that the ICCs of the Cobb and the centroid methods were both excellent (greater than 0.819 vs. greater than 0.801), and their MADs were similar (less than 2.29 vs. less than 2.53) for intraobserver comparisons. Interobserver comparisons showed that ICCs and MADs were dependent on the severity of coronal curvature, and the ICCs of the Cobb method (greater than 0.698) were greater than that of the centroid method (greater than 0.507). Furthermore, MAD values for the Cobb method were lower than that for the centroid method (less than 3.59 vs. less than 6.07). Moreover, these results are contradictory to the previous study, which showed the higher reliability of the centroid method in measures of adolescent scoliosis.
Conclusions: In the present study, the reliability of the centroid method was found to be more susceptible to the severity of disease in older patients, despite its demonstrated greater reliability in adolescent scoliosis. Our findings show that the selective use of these two methods in old and young patients can increase the reliabilities of measurements made.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.spinee.2012.11.051 | DOI Listing |
Int J Biol Macromol
January 2025
College of Information Science and Engineering, Northeastern University, China.
Protein-protein interactions (PPI) are crucial for understanding numerous biological processes and pathogenic mechanisms. Identifying interaction sites is essential for biomedical research and targeted drug development. Compared to experimental methods, accurate computational approaches for protein-protein interaction sites (PPIS) prediction can save significant time and costs.
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Rd., Haidian District, Beijing, China.
Background: This study aims to comprehensively evaluate the predictive accuracy of six widely used toric intraocular lens (IOL) calculators in eyes undergoing cataract surgery with toric IOL implantation.
Methods: This retrospective study reviewed 53 eyes of 53 patients that underwent cataract extraction with toric IOL implantation using Zeiss 709 M. Six toric IOL calculators were evaluated: Barrett toric calculator (with predicted PCA, measured PCA, and TK), Kane formula (predicted PCA), and EVO 2.
PeerJ
January 2025
Centro de Tecnologia e Desenvolvimento Regional, Universidade Federal da Paraíba, João Pessoa, Paraíba, Brazil.
Background: Fruits are sources of bioactive compounds such as phenolics that bring health benefits to consumers. The addition of fruit products and microorganisms with probiotic potential in fermented goat milk can facilitate the acquisition of these benefits through diet. In this sense, the objective of this study was to evaluate the effect of incorporating a mixture of ingredients from jaboticaba (), jambolana (), and mandacaru () fruits on fermentation parameters (pH, titratable acidity, viability of the native culture CNPC003 and the starter culture), associated with pigmentation (phenolic compound content and color) through experimental mixture design.
View Article and Find Full Text PDFTransl Vis Sci Technol
January 2025
Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA.
Purpose: Although the lens undoubtedly plays a major role in presbyopia, altered lens function could be in part secondary to age-related changes of the ciliary muscle. Ciliary muscle changes with accommodation have been quantified using optical coherence tomography, but so far these studies have been limited to quantifying changes in ciliary muscle thickness, mostly at static accommodative states. Quantifying ciliary muscle thickness changes does not effectively capture the dynamic anterior-centripetal movement of the ciliary muscle during accommodation.
View Article and Find Full Text PDFJ Endod
January 2025
Faculdade São Leopoldo Mandic, Instituto de Pesquisa São Leopoldo Mandic, Área de Endodontia, Campinas, São Paulo, Brasil.
Introduction: This study evaluated the shaping ability of the single-file XP-endo Shaper (XP-S) system, employing an extended working time, and the Reciproc Blue #40/.06 (REC) instrument during the preparation of oval-shaped canals.
Methods: Eleven pairs of contralateral premolars with a single canal were divided into two groups (n = 11) according to the canal preparation protocol: XP-S (with an additional 45 seconds of instrumentation) and REC.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!