Purpose: The purpose of this study was to investigate and optimize anterior cruciate ligament (ACL) femoral outside-in drilling technique with a goal of anatomic restoration of the footprint morphologic length, width, area, and angular orientation.

Methods: Ex vivo, computer navigation was used to create virtual 3-dimensional maps of femoral bone tunnels for ACL drill guide pin insertion paths on small, medium, and large models of averaged femora considering various pin insertion angles to the femur. We then determined which pin insertion angle resulted in an ACL femoral footprint optimally matching normal human anatomic length, width, area, and angular orientation of the footprint long axis.

Results: During outside-in drilling of the ACL femoral socket, a guide pin entrance angle of 60° to a line perpendicular to the femoral anatomic axis, combined with a guide pin entrance angle of 20° to the transepicondylar axis, results in the closest approximation of the gold standard of normal anatomic morphology of the human knee ACL femoral footprint length, width, area, and angular orientation.

Conclusions: During outside-in drilling of the ACL femoral socket, a guide pin entrance angle of 60° to a line perpendicular to the femoral anatomic axis, combined with a guide pin entrance angle of 20° to the transepicondylar axis, results in optimal reconstruction of the normal human anatomic ACL femoral footprint length, width, area, and angular orientation.

Clinical Relevance: We describe arthroscopic landmarks for anatomic ACL femoral socket creation that may be considered by practicing arthroscopic surgeons in the operating room, without open dissection or fluoroscopy and unaffected by type of drill guide or variations in the thickness of the femoral soft-tissue envelope.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2012.10.007DOI Listing

Publication Analysis

Top Keywords

acl femoral
28
guide pin
20
femoral socket
16
femoral footprint
16
outside-in drilling
16
length width
16
width area
16
area angular
16
pin entrance
16
entrance angle
16

Similar Publications

Background: Advances in technology and affordability of ultrasound (US) have expanded its use in the evaluation of musculoskeletal injuries. However, US accuracy for diagnosing anterior cruciate ligament (ACL) injuries remains inconsistently reported in the literature.

Hypothesis/purpose: Systematically review the literature and perform a meta-analysis to statistically evaluate the accuracy of US in diagnosing ACL tears.

View Article and Find Full Text PDF

This technical note explores the novel use of an imageless robotic surgical system for simultaneous unicompartmental knee arthroplasty (UKA) and anterior cruciate ligament reconstruction (ACLR). Knee osteoarthritis (OA) and anterior cruciate ligament (ACL) insufficiency are common conditions that traditionally require separate management. The integration of robotic assistance offers enhanced precision in surgical procedures, addressing both medial compartment OA and ACL insufficiency in a single operation.

View Article and Find Full Text PDF

The number of revision anterior cruciate ligament reconstruction (RACLR) procedures is increasing in proportion to the increase in the number of anterior cruciate ligament reconstruction (ACLR) procedures. Although approximately 50-75% of these procedures can be performed in a single-stage procedure, not all of them can. The choice of graft may influence the results of RACLR.

View Article and Find Full Text PDF

Revision of anterior cruciate ligament reconstruction presents various challenges not encountered in the primary settings, including malpositioned tunnels, tunnel widening, and the lack of consensus on the ideal graft to be used. This Technical Note describes a one-stage anterior cruciate ligament reconstruction revision using a bone-patellar tendon-bone autograft combined with lateral extra-articular tenodesis. This technique represents the ideal approach to tackle complex revision cases primarily characterized by tibial and femoral tunnel osteolysis and rotational knee instability.

View Article and Find Full Text PDF

There is renewed interest in anterior cruciate ligament (ACL) preservation techniques. Prior studies have shown good outcomes and low failure rates with ACL preservation in patients with good tissue quality and more proximal tears. We describe a technique intended to assist surgeons in obtaining maximal length of the ACL stump during ACL preservation surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!