Reevaluation of (241)Am content in the USTUR case 0102 leg phantom.

Health Phys

Department of Nuclear Engineering and Health Physics, Idaho State University, 921 South 8th Ave., Stop 8103, Pocotello, ID 83209, USA.

Published: January 2013

The (241)Am contents in the United States Transuranium and Uranium Registries' (USTUR) case 0102 leg phantom were previously estimated to be 1,243 ± 11 Bq. Recent analysis of the computed tomography images of the phantom revealed multiple bone structures missing from various regions of the phantom skeleton including: posterior ilium, anterior ilium, ischium, femur proximal end, femur middle shaft, femur distal end, patella, tibia distal shaft, fibula distal shaft, and fibula distal end. Additionally, the fifth metatarsal and all of the fifth-digit phalanges were found to be completely missing from the foot. A three-dimensional (3D) model of the leg phantom was created using 3D-Doctor software. Volumes of missing bone structures were outlined separately based on the anatomical assessment of those structures. Weights of the missing bone samples were calculated. Consequently, the value of total( 241)Am activity in the USTUR leg phantom is 1,218 ± 11 Bq. This activity is about 2.0% less than the previously published value of 1,243 ± 11 Bq. External gamma detector response was simulated considering both activity values (1,243 and 1,218 Bq) across the five different locations along the USTUR leg phantom: foot, middle leg, knee, middle thigh, and hip. Each counting position was chosen such that it was above the missing bone structure locations. The highest difference observed between the two counting efficiencies (each corresponding to the two different quantities of estimated activity) was 8.2% and 9.4% for locations above the foot and middle thigh, respectively. Other counting locations (middle leg, knee, and hip) showed efficiency variations of about 1%.

Download full-text PDF

Source
http://dx.doi.org/10.1097/hp.0b013e318269bf81DOI Listing

Publication Analysis

Top Keywords

leg phantom
20
missing bone
12
ustur case
8
case 0102
8
0102 leg
8
bone structures
8
distal shaft
8
shaft fibula
8
fibula distal
8
ustur leg
8

Similar Publications

Noise-matched total-likelihood-based bilateral filter: Experimental feasibility in a benchtop photon-counting CBCT system.

Phys Med

January 2025

Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-eup, Dalseong-gun, Daegu, 42988, Republic of Korea. Electronic address:

Purpose: Material decomposition induces substantial noise in basis images and their synthesized computed tomography (CT) images. A likelihood-based bilateral filter was previously developed as a neighborhood filter that effectively reduces noise. However, this method is sensitive to image contrast, and the noise texture needs improvement.

View Article and Find Full Text PDF

The present study aimed to assess organ doses and the associated cancer risks related to secondary radiation (photons and neutrons) exposure during 3D Conformational Radiotherapy (3D-CRT) for patients with prostate cancer in Algeria. To this purpose, a detailed geometric Monte Carlo (MC) modeling of the LINAC, combined with a hybrid whole-body phantom was carried out. The secondary radiation doses were calculated in patient's organs, both within and outside the field.

View Article and Find Full Text PDF

MMD-Net: Image domain multi-material decomposition network for dual-energy CT imaging.

Med Phys

November 2024

Research Center for Advanced Detection Materials and Medical Imaging Devices, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China.

Background: Multi-material decomposition is an interesting topic in dual-energy CT (DECT) imaging; however, the accuracy and performance may be limited using the conventional algorithms.

Purpose: In this work, a novel multi-material decomposition network (MMD-Net) is proposed to improve the multi-material decomposition performance of DECT imaging.

Methods: To achieve dual-energy multi-material decomposition, a deep neural network, named as MMD-Net, is proposed in this work.

View Article and Find Full Text PDF

Background: Streptococcal toxic shock syndrome (STSS) is a notifiable disease under Japan's Infectious Disease Control Law and has become a pandemic following COVID-19. STSS often leads to necrotizing fasciitis, with a mortality rate exceeding 30%. Even in surviving patients, limb amputations are common.

View Article and Find Full Text PDF

Background: Endovascular procedures are the preferred method for treating peripheral arterial disease. However, limited imaging options during these procedures, such as X-rays and contrast media, expose patients and healthcare professionals to potentially harmful radiation. This study introduces a robotic ultrasound system (RUSS) for navigating endovascular procedures in order to reduce radiation and provide additional information.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!