Objectives: To assess whether the use of iodinated contrast medium increases the incidence of acute kidney injury in ICU patients, compared with patients not receiving iodinated contrast medium.

Design: Prospective observational matched cohort study.

Setting: Two ICUs in two tertiary teaching hospitals.

Patients: A total of 380 adults were included (20% more than once), before an iodinated contrast medium infusion (contrast inclusions, n=307) or before an intrahospital transfer without iodinated contrast medium infusion (control inclusions, n=170).

Interventions: None.

Measurements And Main Results: Among contrast inclusions, iodinated contrast medium-associated acute kidney injury occurred after 23 administrations (7.5%) according to the Acute Kidney Injury Network definition (stage≥1, over 48 hr). As expected, a broader definition (≥25% increase in serum creatinine over 72 hr) yielded a greater incidence (16%). In 146 pairs of contrast and control inclusions, matched on propensity for iodinated contrast medium infusion, the incidence of acute kidney injury was similar (absolute difference in incidence, 0%; 95% confidence interval, -5.2; 5.2%), Acute Kidney Injury Network definition). Hospital mortality was also similar in 71 contrast and 71 control patients included only once and matched the same way. Contrary to iodinated contrast medium infusion (odds ratio, 1.57; 95% confidence interval, 0.69-3.53), the Sequential Organ Failure Assessment score at inclusion (odds ratio, 1.18; 95% confidence interval, 1.07-1.31) and the number of other nephrotoxic agents (odds ratio, 1.38; 95% confidence interval, 1.03-1.85) were independent risk factors for acute kidney injury.

Conclusions: The specific toxic effect of monomeric nonionic low-osmolar iodinated contrast medium in ICU patients with multiple renal aggressions seemed minimal. Severity of disease and the global nephrotoxic burden were risk factors for acute kidney injury, regardless of iodinated contrast medium infusion.

Download full-text PDF

Source
http://dx.doi.org/10.1097/CCM.0b013e318275871aDOI Listing

Publication Analysis

Top Keywords

iodinated contrast
40
acute kidney
32
contrast medium
32
kidney injury
28
medium infusion
20
95% confidence
16
confidence interval
16
contrast
14
odds ratio
12
iodinated
10

Similar Publications

Photon-counting mammography is an emerging modality that allows for spectral imaging and provides a differentiation of material compositions. The development of photon-counting mammography-specific contrast agents has yet to be explored. In this study, the contrast, sensitivity, and organ dose between silver sulfide nanoparticles (AgS-NPs) and a clinically approved iodinated agent (iopamidol) were investigated using a contrast-embedded gradient ramp phantom and a prototype scanner.

View Article and Find Full Text PDF

Background: To define optimal parameters for the evaluation of vessel visibility in intracranial stents (ICS) and flow diverters (FD) using photon-counting detector computed tomography angiography (PCD-CTA) with spectral reconstructions.

Methods: We retrospectively analyzed consecutive patients with implanted ICS or FD, who received a PCD-CTA between April 2023 and March 2024. Polyenergetic, virtual monoenergetic, pure lumen, and iodine reconstructions with different keV levels (40, 60, and 80) and reconstruction kernels (body vascular [Bv]48, Bv56, Bv64, Bv72, and Bv76) were evaluated by two radiologists with regions of interests and Likert scales.

View Article and Find Full Text PDF

Coronary artery disease (CAD) remains a leading cause of morbidity and mortality worldwide, necessitating advancements in diagnostic techniques. Coronary CT angiography (CCTA) has emerged as a pivotal non-invasive tool for evaluating coronary artery anatomy and detecting atherosclerotic plaque burden with high spatial resolution. This review explores the evolution of CCTA, highlighting its technological advancements, clinical applications, and challenges.

View Article and Find Full Text PDF

Background: K-edge subtraction (KES) imaging is a dual-energy imaging technique that enhances contrast by subtracting images taken with x-rays that are above and below the K-edge energy of a specified contrast agent. The resulting reconstruction spatially identifies where the contrast agent accumulates, even when obscured by complex and heterogeneous distributions of human tissue. This method is most successful when x-ray sources are quasimonoenergetic and tunable, conditions that have traditionally only been met at synchrotrons.

View Article and Find Full Text PDF

Population-level impact of COVID-19 on thyroid function tests: Results from a repeated cross-sectional study.

J Infect Public Health

January 2025

Department of Genomic Medicine, Division of Biochemistry, Molecular Biology, and Nutrition, University Hospital of Nancy, Nancy F-54000, France; Reference Center for Inborn Errors of Metabolism (ORPHA67872), University Hospital of Nancy, Nancy F-54000, France; Faculty of Medicine of Nancy, University of Lorraine, Nancy F-54000, France; INSERM UMR_S 1256, Nutrition, Genetics, and Environmental Risk Exposure (NGERE), Nancy F-54000, France. Electronic address:

Purpose: Reports have highlighted thyroid abnormalities, including subacute thyroiditis and thyrotoxicosis, in COVID-19 patients, with a potential link between thyroid dysfunction and disease severity. However, population-level studies on COVID-19's impact on thyroid hormone levels are limited. We aimed to assess the impact of the COVID-19 pandemic on thyroid function tests at the population level.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!