A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Turn-on colorimetric sensor for ultrasensitive detection of thrombin using fibrinogen-gold nanoparticle conjugate. | LitMetric

Turn-on colorimetric sensor for ultrasensitive detection of thrombin using fibrinogen-gold nanoparticle conjugate.

Analyst

Tianjin Key Laboratory for Modern Drug Delivery & High-Efficiency, School of Pharmaceutical Science and Technology, Tianjin University, Tianjin 300072, People's Republic of China.

Published: March 2013

A simple, colorimetric 'turn on' sensor for ultrasensitive detection of thrombin has been developed using fibrinogen-modified gold nanoparticles (Fib-Au NPs). The assay was based on the thrombin-fibrinogen interaction which is part of the physiological process of blood clotting. The fibrinogen was immobilized on the surface of 96-well plate offering reactive N-oxysuccinimide esters (referred to as NOS group) surface. Introducing thrombin and Fib-Au NPs into the fibrinogen-bound 96-well plate induced the immobilization of Fib-Au NPs on the surface of 96-well plate through the thrombin mediated conversion of soluble fibrinogen to insoluble cross-linked fibrin. Such process could be detected visually post HAuCl(4)-NH(2)OH redox reaction catalyzed by the Au NPs. The parameters governing the performance of the assay have been optimized. The detection limit was 3.2 fM, corresponding to 0.16 amol thrombin in 50 μL of sample. Other proteins, such as bovine serum albumin (BSA), pepsin, trypsin, hemoglobin, lysozyme, and cytochrome c did not show interference with the assay of thrombin. In addition, the work demonstrates the feasibility of thrombin detection in a complex matrix, showing potential for rapid medical diagnostics.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c2an36269dDOI Listing

Publication Analysis

Top Keywords

fib-au nps
12
96-well plate
12
sensor ultrasensitive
8
ultrasensitive detection
8
detection thrombin
8
surface 96-well
8
thrombin
7
turn-on colorimetric
4
colorimetric sensor
4
detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!