Background: Still picture transmission was performed using a telemedicine system in an Emergency Medical Service (EMS) during a prospective, controlled trial. In this ancillary, retrospective study the quality and content of the transmitted pictures and the possible influences of this application on prehospital time requirements were investigated.
Methods: A digital camera was used with a telemedicine system enabling encrypted audio and data transmission between an ambulance and a remotely located physician. By default, images were compressed (jpeg, 640 x 480 pixels). On occasion, this compression was deactivated (3648 x 2736 pixels). Two independent investigators assessed all transmitted pictures according to predefined criteria. In cases of different ratings, a third investigator had final decision competence. Patient characteristics and time intervals were extracted from the EMS protocol sheets and dispatch centre reports.
Results: Overall 314 pictures (mean 2.77 ± 2.42 pictures/mission) were transmitted during 113 missions (group 1). Pictures were not taken for 151 missions (group 2). Regarding picture quality, the content of 240 (76.4%) pictures was clearly identifiable; 45 (14.3%) pictures were considered "limited quality" and 29 (9.2%) pictures were deemed "not useful" due to not/hardly identifiable content. For pictures with file compression (n = 84 missions) and without (n = 17 missions), the content was clearly identifiable in 74% and 97% of the pictures, respectively (p = 0.003). Medical reports (n = 98, 32.8%), medication lists (n = 49, 16.4%) and 12-lead ECGs (n = 28, 9.4%) were most frequently photographed. The patient characteristics of group 1 vs. 2 were as follows: median age - 72.5 vs. 56.5 years, p = 0.001; frequency of acute coronary syndrome - 24/113 vs. 15/151, p = 0.014. The NACA scores and gender distribution were comparable. Median on-scene times were longer with picture transmission (26 vs. 22 min, p = 0.011), but ambulance arrival to hospital arrival intervals did not differ significantly (35 vs. 33 min, p = 0.054).
Conclusions: Picture transmission was used frequently and resulted in an acceptable picture quality, even with compressed files. In most cases, previously existing "paper data" was transmitted electronically. This application may offer an alternative to other modes of ECG transmission. Due to different patient characteristics no conclusions for a prolonged on-scene time can be drawn. Mobile picture transmission holds important opportunities for clinical handover procedures and teleconsultation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3568016 | PMC |
http://dx.doi.org/10.1186/1757-7241-21-3 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Innovation Laboratory for Sciences and Technologies of Energy Materials of Fujian Province (IKKEM), Xiamen University, Xiamen 361005, China.
The molecule-electrode interface can regulate both the efficiency and pathways of electron transport through single-molecule junctions (SMJs). The electromechanics of the interface has proven crucial in exposing the underlying mechanisms of electron transmission through SMJs, providing a theoretical base and practical guidance for designing and constructing functional molecular devices. Here we encompass several currently developed methodologies for investigating the electromechanics of molecule-electrode interface and provide an account of their application in elucidating the effects of the molecule-electrode interface on electron transport properties of SMJs.
View Article and Find Full Text PDFMicrobiol Spectr
January 2025
Instituto de Medicina Tropical Alexander von Humboldt, Universidad Peruana Cayetano Heredia, Lima, Peru.
The emergence of carbapenem-resistant (CRKP) poses a significant public health threat, particularly in low- and middle-income countries (LMICs) with limited surveillance and treatment options. This study examines the genetic diversity, resistance patterns, and transmission dynamics of 66 CRKP isolates recovered over 5 years (2015-2019) after the first case of CRKP was identified at a tertiary care hospital in Lima, Peru. Our findings reveal a shift from to as the dominant carbapenemase gene after 2017.
View Article and Find Full Text PDFmSystems
January 2025
Institute for Infection Prevention and Control, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
The surveillance of mobile genetic elements facilitating the spread of antimicrobial resistance genes has been challenging. Here, we tracked both clonal and plasmid transmission in colistin- and carbapenem-resistant using short- and long-read sequencing technologies. We observed three clonal transmissions, all containing Incompatibility group (Inc) L plasmids and New Delhi metallo-beta-lactamase , although not co-located on the same plasmid.
View Article and Find Full Text PDFOphthalmologie
January 2025
Klinik für Augenheilkunde, Universitätsaugenklinik Düsseldorf, Moorenstr. 5, 40225, Düsseldorf, Deutschland.
Due to the global effects of climate change numerous infectious diseases are increasingly spreading to regions that were previously hardly or only slightly affected. As ocular involvement is possible in many of these infectious diseases, we must also adapt to new pathogens and clinical pictures in Germany in the medium to long term. Using selected bacterial, viral and mycotic pathogens and diseases as examples, the causes of the increase in dissemination and the consequences for ophthalmology are presented.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Sustainable Crop Production (DI.PRO.VE.S.), Università Cattolica del Sacro Cuore, 29122 Piacenza, Italy.
The paper presents a double-radio wireless multimedia sensor node (WMSN) with a camera on board, designed for plant proximal monitoring. Camera sensor nodes represent an effective solution to monitor the crop at the leaf or fruit scale, with details that cannot be retrieved with the same precision through satellites or unnamed aerial vehicles (UAVs). From the technological point of view, WMSNs are characterized by very different requirements, compared to standard wireless sensor nodes; in particular, the network data rate results in higher energy consumption and incompatibility with the usage of battery-powered devices.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!