Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments.

J Endod

Division of Endodontics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada.

Published: February 2013

Introduction: The performance and mechanical properties of nickel-titanium (NiTi) instruments are influenced by factors such as cross-section, flute design, raw material, and manufacturing processes. Many improvements have been proposed by manufacturers during the past decade to provide clinicians with safer and more efficient instruments.

Methods: The mechanical performance of NiTi alloys is sensitive to their microstructure and associated thermomechanical treatment history. Heat treatment or thermal processing is one of the most fundamental approaches toward adjusting the transition temperature in NiTi alloy, which affects the fatigue resistance of NiTi endodontic files. The newly developed NiTi instruments made from controlled memory wire, M-Wire (Dentsply Tulsa Dental Specialties, Tulsa, OK), or R-phase wire represent the next generation of NiTi alloys with improved flexibility and fatigue resistance. The advantages of NiTi files for canal cleaning and shaping are decreased canal transportation and ledging, a reduced risk of file fracture, and faster and more efficient instrumentation. The clinician must understand the nature of different NiTi raw materials and their impact on instrument performance because many new instruments are introduced on a regular basis.

Results: This review summarizes the metallurgical properties of next-generation NiTi instruments, the impact of thermomechanical treatment on instrument flexibility, and the resistance to cyclic fatigue and torsion.

Conclusions: The aim of this review was to provide clinicians with the knowledge necessary for evidence-based practices, maximizing the benefits from the selection and application of NiTi rotary instruments for root canal treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joen.2012.11.005DOI Listing

Publication Analysis

Top Keywords

thermomechanical treatment
12
niti instruments
12
niti
10
provide clinicians
8
niti alloys
8
fatigue resistance
8
instruments
6
treatment
5
current challenges
4
challenges concepts
4

Similar Publications

Design, development and performance of a Fe-Mn-Si-Cu alloy for bioabsorbable medical implants.

J Mater Chem B

January 2025

SAES Getters S.p. A., Viale Italia 77, 20045 Lainate (MI), Italy.

Bioabsorbable metallic alloys constitute a very challenging and innovative field, mainly aimed to develop the next generation of temporary medical implants. Degradation data, biological and tests are of major importance in particular for complex alloys, in which the individual element additions could enhance material performance and add functionalities. In this study, a novel Fe-Mn-Si-Cu alloy was carefully designed for vascular and blood-contact applications, and its microstructure, mechanical behavior, degradation behavior and biological performances were investigated accordingly.

View Article and Find Full Text PDF

3D printed reservoir-like vaginal rings for antibiotic delivery.

Int J Pharm

January 2025

Sezione di Tecnologia e Legislazione Farmaceutiche "Maria Edvige Sangalli", Dipartimento di Scienze Farmaceutiche, Università degli Studi di Milano, via Giuseppe Colombo 71, 20133, Milano, Italy.

Targeting the development of 3D printed reservoir-like vaginal rings (VRs) intended to fulfill the needs of precision medicine, prototypes ensuring prolonged release of metronidazole (MTZ) were preliminary manufactured and tested. Indeed, this drug represents the first-line therapy against bacterial vaginosis, which would especially benefit from convenient as well as easy dose adjustment and from more than 48 h continuous release, thus avoiding barely tolerated and repeated administrations. Starting from a soft thermoplastic elastomer (TPE), hollow ring structures were successfully printed at 190 °C and then extemporaneously filled with drug-loaded, in-situ-crosslinking hydrogel formulations based on alginate (ALG).

View Article and Find Full Text PDF

Cleavable bio-based epoxy resin systems are emerging, eco-friendly, and promising alternatives to the common thermoset ones, providing quite comparable thermo-mechanical properties while enabling a circular and green end-of-life scenario of the composite materials. In addition to being designed to incorporate a bio-based resin greener than the conventional fully fossil-based epoxies, these formulations involve cleaving hardeners that enable, under mild thermo-chemical conditions, the total recycling of the composite material through the recovery of the fiber and matrix as a thermoplastic. This research addressed the characterization, processability, and recyclability of a new commercial cleavable bio-resin formulation (designed by the R-Concept company) that can be used in the fabrication of fully recyclable polymer composites.

View Article and Find Full Text PDF

Objective: The present study aimed to evaluate the phase transformation behavior and elemental analysis of thermomechanical-treated nickel-titanium (NiTi) rotary instruments, TruNatomy (Dentsply Sirona), HyFlex CM (coltene, Whaledent), and Neoendo Flex (Orikam healthcare India), using differential scanning calorimetry (DSC), X-ray diffraction (XRD), and energy dispersive X-ray spectrometry.

Materials And Methods: A total of 18 NiTi rotary instruments, TruNatomy, Hyflex CM, Neoendo Flex, taper. 04, size 25 (except TruNatomy, size 26) were selected and were divided into three groups ( = 6).

View Article and Find Full Text PDF

Purpose: The current study aimed to compare modified Polyether-ether-ketone's fracture resistance and failure mode versus lithium disilicate glass-ceramic endocrowns.

Materials And Methods: A total of 16 butt-joint endocrown specimens on mandibular second molar teeth were fabricated and divided into two equivalent groups; Pressable modified Polyether-ether-ketone (PEEK) (BioHPP) and Pressable lithium disilicate glass ceramic (IPS e.max Press).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!