Objectives: Continuous-flow left ventricular assist devices have become the standard of care for patients with heart failure requiring mechanical circulatory support as a bridge to transplant. However, data on long-term post-transplant survival for these patients are limited. We evaluated the effect of continuous-flow left ventricular assist devices on postcardiac transplant survival in the current era.

Methods: All patients who received a continuous-flow left ventricular assist device as a bridge to transplant at a single center from June 2005 to September 2011 were evaluated.

Results: Of the 167 patients who received a continuous-flow left ventricular assist device as a bridge to transplant, 77 (46%) underwent cardiac transplantation, 27 died before transplantation (16%), and 63 (38%) remain listed for transplantation and continued with left ventricular assist device support. The mean age of the transplanted patients was 54.5 ± 11.9 years, 57% had an ischemic etiology, and 20% were women. The overall mean duration of left ventricular assist device support before transplantation was 310 ± 227 days (range, 67-1230 days). The mean duration of left ventricular assist device support did not change in patients who had received a left ventricular assist device in the early period of the study (2005-2008, n = 62) compared with those who had received a left ventricular assist device later (2009-2011, n = 78, 373 vs 392 days, P = NS). In addition, no difference was seen in survival between those patients supported with a left ventricular assist device for fewer than 180 days or longer than 180 days before transplantation (P = NS). The actuarial survival after transplantation at 30 days and 1, 3, and 5 years by Kaplan-Meier analysis was 98.7%, 93.0%, 91.1%, and 88.0%, respectively.

Conclusions: The short- and long-term post-transplant survival for patients bridged with a continuous-flow left ventricular assist device in the current era has been excellent. Furthermore, the duration of left ventricular assist device support did not affect post-transplant survival. The hemodynamic benefits of ventricular unloading with continuous-flow left ventricular assist devices, in addition to their durability and reduced patient morbidity, have contributed to improved post-transplant survival.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2012.09.095DOI Listing

Publication Analysis

Top Keywords

left ventricular
56
ventricular assist
56
assist device
40
continuous-flow left
28
assist devices
16
post-transplant survival
16
device support
16
ventricular
15
left
14
assist
14

Similar Publications

Automated Classification of Cardiac Arrhythmia using Short-Duration ECG Signals and Machine Learning.

Biomed Phys Eng Express

January 2025

Electronics and Communication Engineering, Rajiv Gandhi University, Rono Hills, Doimukh, ITANAGAR, Itanagar, Arunachal Pradesh, 791112, INDIA.

Accurate detection of cardiac arrhythmias is crucial for preventing premature deaths. The current study employs a dual-stage Discrete Wavelet Transform (DWT) and a median filter to eliminate noise from ECG signals. Subsequently, ECG signals are segmented, and QRS regions are extracted for further preprocessing.

View Article and Find Full Text PDF
Article Synopsis
  • Hyperacute cardiac CT is more effective than transthoracic echocardiography in detecting intracardiac thrombus, but its routine use is limited due to costs and risks.
  • A study of 1,136 ischemic stroke or TIA patients found that longer arterial input function (AIF) dispersal times correlate with the presence of thrombus and worse outcomes, with a specific cutoff of 33 seconds indicating higher risk.
  • The findings support using AIF dispersal measurements to help identify patients who may benefit from cardiac imaging, potentially optimizing resource use in stroke management.
View Article and Find Full Text PDF

Objective: In patients with primary hypertension (PH), left ventricular hypertrophy (LVH) is a critical predictor of cardiovascular events. We aimed to identify clinical and laboratory predictors of LVH in patients with PH.

Methods: This retrospective cohort study included 2321 patients with PH at the Fifth Affiliated Hospital of Xinjiang Medical University from December 2022 to January 2024.

View Article and Find Full Text PDF

Obscurin is a giant protein that coordinates diverse aspects of striated muscle physiology. Obscurin immunoglobulin domains 58/59 (Ig58/59) associate with essential sarcomeric and Ca2+ cycling proteins. To explore the pathophysiological significance of Ig58/59, we generated the Obscn-ΔIg58/59 mouse model, expressing obscurin constitutively lacking Ig58/59.

View Article and Find Full Text PDF

Importance: Multisystem inflammatory syndrome in children (MIS-C) is a life-threatening complication of COVID-19 infection. Data on midterm outcomes are limited.

Objective: To characterize the frequency and time course of cardiac dysfunction (left ventricular ejection fraction [LVEF] <55%), coronary artery aneurysms (z score ≥2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!