Objective: To describe the use of automated blood salvage devices for autotransfusion in dogs.
Technique: Blood salvage devices can be used to collect blood from the intraoperative surgical field or postsurgical drainage sites. The salvage device washes cells in 0.9% saline, removing plasma proteins, other cellular components, and activators of coagulation and inflammation. Washed red blood cells may be safely returned to the patient, minimizing the need for allogeneic blood transfusions.
Significance: Blood salvage has been safely used in human medicine for decades and is feasible in veterinary medicine. Potential advantages include reduced reliance on banked blood for massive transfusions and minimization of morbidities associated with the use of allogeneic and stored blood products. Concerns about the safety of salvaged blood have been largely dispelled in human medicine but further investigation regarding the safety of such procedures in veterinary patients is warranted.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/vec.12017 | DOI Listing |
Low Urin Tract Symptoms
January 2025
Department of Urology, Institute of Urology (Laboratory of Reconstructive Urology), West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China.
Aim: This study aimed to analyze the clinical efficacy and safety of autologous fascial pubovaginal sling (AFPVS) surgery in treating recurrent stress urinary incontinence (SUI) following the failure of mid-urethral sling procedures.
Methods: A retrospective analysis was conducted on the clinical data of SUI patients who underwent AFPVS at our hospital between 2008 June and 2024 June following the failure of mid-urethral sling procedures. The analysis included basic information, surgical parameters, and postoperative complications.
Am J Sports Med
January 2025
Department of Orthopaedic Surgery, Washington University School of Medicine in St. Louis, St. Louis, Missouri, USA.
Background: Osteochondral allograft transplantation (OCA) is well established as a viable chondral restoration procedure for the treatment of symptomatic, focal chondral defects of the knee. The efficacy of secondary OCA in the setting of failed index cartilage repair or restoration is poorly understood.
Purpose: To evaluate radiographic and clinical outcomes, failures, and reoperations after OCA after failed index cartilage repair or restoration of the knee.
J Hand Surg Eur Vol
January 2025
Hand & Wrist Unit, Genolier Campus, Vaud, Switzerland.
J Hand Surg Eur Vol
January 2025
Wrightington Hospital, Wigan, Lancashire, UK.
Wrist arthrodesis performed to salvage a failed total wrist arthroplasty can be challenging owing to bone loss and poor soft tissue quality. This article focuses on the evidence base and our experience as a tertiary unit in managing this cohort of patients. A systematic and meticulous approach is required to attempt to minimize complications.
View Article and Find Full Text PDFIJU Case Rep
January 2025
Department of Urology Bendigo Health Bendigo Victoria Australia.
Introduction: This report describes late erosion of an Adjustable Transobturator Male System device which was inserted for post-prostatectomy incontinence. The Adjustable Transobturator Male System device eroded the bulbar urethra 5 years post insertion, despite initial improvement of symptoms.
Case Presentation: Following an open radical retropubic prostatectomy, a 64 year-old male patient developed post-prostatectomy incontinence.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!