The correction of setup and laser instabilities in a single-comb interferometric measurement using optical sampling by laser-cavity tuning is investigated. A two-reference solution that allows full correction of the interferogram is presented. The technique is compared to a slightly simpler one-reference correction. For the one-reference case, all the subtleties involved in this partial correction and the dependence between the achievable measurement accuracy and the setup parameters are highlighted. The parameters considered are the comb bandwidth, the laser-frequency noise, the required spectral resolution, the cavity scan speed, and the length of the delay line. For both referencing approaches, experimental results using a fiber delay line of 10 km and a 100 MHz mode-locked laser with its repetition rate swept at 500 Hz are shown.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.52.000248DOI Listing

Publication Analysis

Top Keywords

optical sampling
8
sampling laser-cavity
8
laser-cavity tuning
8
fully referenced
4
referenced single-comb
4
single-comb interferometry
4
interferometry optical
4
correction
4
tuning correction
4
correction setup
4

Similar Publications

This research examined the distinction between organic and conventional mango fruits, chips, and juice using portable near-infrared (NIR) spectroscopy. A comprehensive analysis was conducted on a sample of 100 mangoes (comprising 50 organic and 50 conventional) utilising a portable NIR spectrometer that spans a wavelength range from 900 to 1700 nm. The mangoes were assessed in their entirety and their juice and chip forms.

View Article and Find Full Text PDF

Introduction: Glaucoma is a leading cause of blindness, often progressing asymptomatically until significant vision loss occurs. Early detection is crucial for preventing irreversible damage. The pupillary light reflex (PLR) has proven useful in glaucoma diagnosis, and mobile technologies like the AI-based smartphone pupillometer (AI Pupillometer) offer a promising solution for accessible screening.

View Article and Find Full Text PDF

Introduction: Ultraviolet-induced fluorescence dermoscopy (UVF dermoscopy) is a novel diagnostic technique for identifying and diagnosing numerous skin tumors, inflammatory dermatoses, and infectious diseases. The ultraviolet (UV) band has a wavelength ranging from 10 to 400 nm. When intense UV radiation with shorter wavelengths strikes a target chromophore, visible light (VL) with a longer wavelength and lower energy is produced in the skin.

View Article and Find Full Text PDF

Dermoscopic Features of Diaper Dermatoses in Children: A Descriptive Pilot Study.

Indian Dermatol Online J

November 2024

Department of Dermatology, Venereology, and Leprosy, Gandhi Medical College, Secundarabad, Telangana, India.

Background: Diaper dermatoses broadly refer to skin disorders that occur in the diaper area. Dermoscopy is a non-invasive diagnostic tool that magnifies subsurface structures of the skin that are invisible to the unaided eye.

Aim: To identify and describe the dermoscopic features of dermatoses in the diaper area.

View Article and Find Full Text PDF

Introduction: Recent findings show that visible light, particularly blue light, stimulates melanogenesis in human skin, though the underlying mechanisms remain debated. This study aimed to determine the cell damage threshold of non-ionizing blue light on keratinocytes while preserving their ability to stimulate melanogenesis.

Methods: Human keratinocytes (N = 3) and melanocytes (N = 3) were isolated from skin samples of varying Fitzpatrick skin phototypes and irradiated with blue light (λpeak = 457 nm) and UVA light (λpeak = 385 nm).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!