Measurement of left ventricular mass in rats using electrocardiogram-gated magnetic resonance imaging.

Am J Physiol

Charles A. Dana Research Institute, Beth Israel Hospital, Boston, Massachusetts 02215.

Published: April 1990

AI Article Synopsis

  • The study evaluated ECG-gated MRI for measuring left ventricular (LV) mass in 20 healthy rats and 8 that experienced volume overload from aortic disruption.
  • The method used involved capturing modified short-axis images and calculating LV mass through specific measurements, leading to a strong correlation with postmortem findings (r = 0.98).
  • Results indicated that LV mass measurements were consistent across observers and between diastolic and systolic images, with a noted 40% increase in mass over 6.5 weeks in rats with aortic disruption.

Article Abstract

To evaluate the ability of electrocardiogram (ECG)-gated magnetic resonance (MR) imaging to assess in vivo left ventricular (LV) mass in the rat, we studied 20 healthy adult Sprague-Dawley and Fischer 344 rats and 8 additional rats that underwent scanning after induction of volume overload by aortic leaflet disruption. ECG-gated spin-echo pulse sequences were used to acquire a series of 1-mm thick modified short-axis images of the left ventricle. The area enclosed by the endocardial and epicardial borders of the left ventricle was multiplied by the interslice distance and specific gravity of myocardium to obtain calculated slice mass. Total LV mass was obtained by summing the individual slices. The calculated value for LV mass was then compared with the LV mass as determined at postmortem examination. Linear regression analysis showed an excellent correlation of MR-estimated mass (x) with autopsy-measured LV mass (y) (y = 0.90x + 65, r = 0.98). For this method intraobserved and interobserver slice correlations were 0.97 and 0.96, respectively. There was no significant difference in LV mass as determined from a series of diastolic vs. systolic images in a subset of six animals. Over a mean of 6.5 wk of observation, LV mass increased by 40% in the animals subjected to aortic leaflet disruption. These results demonstrate that MR imaging is highly accurate for the non-invasive in vivo assessment of LV mass in the adult rat.

Download full-text PDF

Source
http://dx.doi.org/10.1152/ajpheart.1990.258.4.H1181DOI Listing

Publication Analysis

Top Keywords

mass
11
left ventricular
8
ventricular mass
8
magnetic resonance
8
resonance imaging
8
aortic leaflet
8
leaflet disruption
8
left ventricle
8
mass determined
8
measurement left
4

Similar Publications

Global concern regarding transformation products (TPs) derived from contaminants, including pesticides, in the environment and during water treatment has been growing markedly. In the present study, we investigated the anti-acetylcholinesterase (AChE) activity of an aqueous solution of the organophosphorus insecticide disulfoton, a toxicological endpoint for determining the acceptable daily intake of disulfoton, both in the presence and the absence of metabolism during chlorination. Disulfoton rapidly reacted with free chlorine and completely disappeared within 0.

View Article and Find Full Text PDF

Globally, drug-impaired driving fatalities now exceed those from drunk driving, urging the need for on-site and roadside detection methods. In this study, a photothermal desorption and reagent-assisted low-temperature plasma ionization miniature ion trap mass spectrometer (PDRA-LTP-ITMS) was developed for on-site detection of drug-impaired driving. The pseudomultiple reaction monitoring (MRM) in PDRA-LTP-ITMS enables continuous ion selection during ion introduction and improved sensitivity to nearly 3-fold compared with the conventional full scan mode.

View Article and Find Full Text PDF

Field-Testing Measures Related to Youth Baseball Hitting Performance.

J Strength Cond Res

February 2025

Sports Medicine and Movement Laboratory, School of Kinesiology, Auburn University, Auburn Alabama.

Bordelon, NM, Agee, TW, Wasserberger, KW, Downs-Talmage, JL, Everhart, KM, and Oliver, GD. Field-testing measures related to youth baseball hitting performance. J Strength Cond Res 39(2): 210-216, 2025-The purpose of the study was to determine the relationship between field tests and youth hitting performance (batted-ball velocity).

View Article and Find Full Text PDF

: The utilization of intra-aortic balloon pump (IABP) and Impella has been suggested as means of left ventricular unloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO) patients. This study aimed to assess the local hemodynamic alterations in VA-ECMO patients through simulation analyses. : In this study, a 0D-3D multiscale model was developed, wherein resistance conditions were employed to define the flow-pressure relationship.

View Article and Find Full Text PDF

Kinematic synergy of speed reduction during stair descent.

Acta Bioeng Biomech

June 2024

1Physical Therapy Course, Faculty of Welfare and Health Science, Oita University, Japan.

: This study aimed to quantify multi-segmental coordination using Uncontrolled Manifold (UCM) analysis to examine the effect of speed reduction on the control of stair descent. : Twenty healthy participants performed stair descent at a self-comfortable pace for normal speed conditions and at a slow speed set to a metronome rhythm of 60 beats/min. UCM analysis was separately conducted for the center of mass (COM) and swing foot, with anteroposterior and vertical movements designated as task variables, and segment angles defined as elemental variables.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!