Long-term evaluation of immediately loaded implants in the edentulous mandible using fixed bridges and platform shifting.

Clin Implant Dent Relat Res

School of Dental Medicine, Stony Brook University, Stony Brook, NY, USA; Department of Oral Surgery and Implant Dentistry, Dental School, University of Frankfurt, Frankfurt, Germany.

Published: August 2014

Background: The immediate loading concept has been extensively documented in the anterior part of the mandible when six primary stable implants are placed, splinted with a fixed prosthesis.

Purpose: The aim of this study was to evaluate the long-term success of immediately occlusal loaded implants with a progressive thread design and platform shifting in the edentulous mandible.

Materials And Methods: Seventy-eight implants placed in 13 patients and were connected with their abutments immediately after surgery. The implants were splinted using a fixed temporary restoration having occlusal contacts in the centric and group function in the lateral movements of the mandible (immediate occlusal loading). The patients were advised to use soft/liquid diet for the first 6 to 8 weeks of healing in order to reduce excessive loading in the bone-to-implant interface. Abutment level impressions were taken without removing the abutments in order to fabricate the final prostheses. The final restorations were delivered 4 to 8 weeks after surgery and cemented temporarily in order to evaluate the peri-implant soft tissue condition at the different time intervals after removal of the restoration. Clinical stability and radiological indices were evaluated at the start of loading, at 3-month interval after loading, and then annually.

Results: After a mean loading period of 75.29 (± 38.18) months, no implant was lost (100% success rate). All clinical indices had values in normal levels. The Periotest values demonstrated a continuous reduction, representing high stability. The crestal bone level was relatively stable and only minimal crestal bone loss was observed in some implants.

Conclusions: Long-term success and stability of the peri-implant tissues around immediately loaded mandibular implants are expected when implants with platform shifting are restored with bridges without abutment removal.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cid.12032DOI Listing

Publication Analysis

Top Keywords

platform shifting
12
loaded implants
8
implants splinted
8
splinted fixed
8
long-term success
8
crestal bone
8
implants
7
loading
6
long-term evaluation
4
evaluation loaded
4

Similar Publications

Effect of Treatment on Steroidome in Women with Multiple Sclerosis.

Int J Mol Sci

February 2025

Department of Neurology, First Faculty of Medicine, Charles University, 128 21 Prague, Czech Republic.

Multiple sclerosis (MS) is a chronic inflammatory neurodegenerative disease of the central nervous system. The manifestation of MS is related to steroid changes during the menstrual cycle and pregnancy. As data focusing on the effect of anti-MS drug treatment on steroidome are scarce, we evaluated steroidomic changes (79 steroids) in 61 female MS patients of reproductive age 39 (29, 47) years (median with quartiles) after treatment with anti-MS drugs on the GC-MS/MS platform and immunoassays (cortisol and estradiol).

View Article and Find Full Text PDF

At uncontrolled intersections, without traffic signals or explicit right-of-way guidance, drivers interacting from different directions depend on their perception and real-time judgment to make strategic decisions about when and how to cross or yield. This uncertainty in decision-making, if misjudged, may result in vehicle collisions. In this study, we developed a networked two-vehicle driving simulator platform, conducted experiments to simulate the interaction between straight-going (SG) and left-turn (LT) vehicles at uncontrolled intersections, and focused on exploring the contributing factors that may influence drivers' crossing decisions.

View Article and Find Full Text PDF

Background: The COVID-19 pandemic presented challenges but also opportunities for growth and innovation in education, especially in advanced practice registered nursing programs. This article explores the rapid shift from in-person to virtual learning and highlights the positive outcomes.

Method: The study examines the impact of this transition on grades, evaluations, preceptor feedback, and board certification pass rates.

View Article and Find Full Text PDF

Stacking induced symmetry breaking and gap opening in Dirac half-metal MnF.

Phys Chem Chem Phys

March 2025

Tianjin Key Laboratory of Film Electronic & Communicate Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin 300384, China.

Two-dimensional ferromagnetic materials have a broader development prospect in the field of spintronics. In particular, the high spin polarization system with half-metallic characteristics can be used as an efficient spin injection electrode. first-principles calculations, we predict that monolayer MnF has Dirac half-metallic properties.

View Article and Find Full Text PDF

Fluorescent labeling techniques have enabled the visualization of various biomolecules, cellular structures, and their associated physiological processes. At the same time, there remains a demand for developing novel fluorescent compounds possessing unique chemical properties for biological imaging. A recently developed class of fluorophores, termed , displays optimal brightness and large Stokes shifts that are ideal for fluorescence microscopy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?