Aim: To compare Holladay equivalent keratometric indices on Scheimpflug tomographer and keratometry on Placido topographer at different optical zones.

Methods: In this observational study, 50 right eyes of 50 patients were recruited. All patients were scanned on both machines. Data on K1, K2, mean keratometry (Km) and meridian of steepest keratometry (MoSK) were collected for central 3 mm and 5 mm optical zones from Holladay Equivalent keratometry report on Scheimpflug tomographer and keratometric data from Placido topographer. Difference (Diff(S-P)) in Km and MoSK were calculated by subtracting corresponding values of Placido from Scheimpflug scans. Concordance was evaluated using paired t tests, the Pearson correlation and Bland-Altman analyses.

Results: Comparing 3 mm vs 5 mm optical zones on each machine, there was no significant difference in Km and MoSK values but Km showed good correlation unlike MoSK. Comparing Scheimpflug versus Placido, Km showed good correlation at all scan sizes, unlike MoSK. 95% limits of agreement between the machines for Km was -1.20D to 1.08D(3 mm) and -1.46D to 1.23D(5 mm); whereas, for MoSK it was -83.05 to 85.82°s(3 mm) and -107.9 to 77.48°s(5 mm) respectively. The Diff(S-P) for Km at 3 mm (-0.45±0.79) was significantly less than that at 5 mm (-0.10±0.70) (p<0.01) whereas Diff(S-P) for MoSK were not significantly different at both optical zones.

Conclusions: Mean keratometry correlated well between Scheimpflug and Placido scans. Axes showed poor correlation between optical zones on same machine and between the machines with same optical zone. Scheimpflug showed flatter keratometry at smaller optical zone. These machines cannot be used interchangeably in refractive surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1136/bjophthalmol-2012-302291DOI Listing

Publication Analysis

Top Keywords

optical zones
12
equivalent keratometric
8
keratometric indices
8
indices scheimpflug
8
holladay equivalent
8
scheimpflug tomographer
8
placido topographer
8
good correlation
8
mosk
6
scheimpflug
5

Similar Publications

Dynamic Accommodation Responses in Subjects Wearing Myopia Control Spectacles Modifying Peripheral Refraction.

Invest Ophthalmol Vis Sci

January 2025

Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain.

Purpose: Peripheral optics have been suggested to play a role in myopia progression, with accommodation responses also considered a potential contributor. This study aimed to investigate whether modifications in peripheral optics through different spectacle lenses affect accommodation responses.

Methods: Dynamic accommodation responses were assessed using a double-pass instrument while switching the target from distance (3 m for 3 seconds) to near (0.

View Article and Find Full Text PDF

3D-printed devices for multiplexed semi-quantitative competitive lateral flow immunoassays.

Anal Methods

January 2025

Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan.

Lateral flow immunoassays (LFIAs) are widely used for the simple and rapid detection of various targets at the point of need. However, LFIAs enabling the simultaneous detection of multiple analytes and the possibility for naked-eye semi-quantitative analysis are facing various challenges, including the requirement of large sample volumes, low efficiency, and accuracy. This is particularly the case for the competitive immunoassay format targeting the detection of low molecular weight compounds, such as, for example, drugs.

View Article and Find Full Text PDF

In current study, microstructural, mechanical and corrosion behaviour were investigated with incorporation of dual reinforced AZ91D surface composites. This research was carried out for enhancement of the bio-degradability in biological environment. The surface composites were successfully fabricated by friction stir processing method with a rotation speed of 800 rpm, travel speed of 80 mm/min and 2.

View Article and Find Full Text PDF

The role of cerebellum in controlling eye movements is well established, but its contribution to more complex forms of visual behavior has remained elusive. To study cerebellar activity during visual attention we recorded extracellular activity of dentate nucleus (DN) neurons in two non-human primates (NHPs). NHPs were trained to read the direction indicated by a peripheral visual stimulus while maintaining fixation at the center, and report the direction of the cue by performing a saccadic eye movement into the same direction following a delay.

View Article and Find Full Text PDF

Crystal Violet (CV) is a vibrant and harmful dye known for its toxicity to aquatic life and potential carcinogenic effects on humans. This study explores the removal of CV through photocatalysis driven by visible light, as well as examining the antibacterial and antibiofilm characteristics of zinc oxide nanoparticles (ZnO NPs) synthesized from the aerial roots of Ficus benghalensis. Various characterization techniques were employed to confirm the optical properties, crystal lattices, and morphology of ZnO NPs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!